Dishwasher Air Gap vs. High Loop: How Each Stops Dirty Water, and the Heights Makers Require

In short

A dishwasher air gap and a high loop do the same two jobs: they keep dirty water from the sink or disposal out of the dishwasher, and they stop the tub from siphoning empty while it fills. The air gap does it with an open break above the counter; the high loop does it with height alone. GE requires an air gap when the drain connection sits less than 18 inches above the floor, and wants a loop of at least 32 inches without one.

Checked against: GE installation instructions, Whirlpool's service manual, Bosch installation instructions, North Carolina and Minnesota plumbing code rulings.

Whirlpool wants the dishwasher drain hose to loop at least 20 inches above the floor. GE asks for 32 inches, Bosch for 33, and LG gives a range of 12 to 40 inches for the end of the hose, measured from the base of the dishwasher rather than the floor. The numbers differ by maker, so the right height for your kitchen is the one in your dishwasher's installation instructions, not a number from a forum.

The reason for the rule is the same everywhere. A dishwasher drains into the same pipe as the kitchen sink, and that pipe can fill up. The drain hose has to rise before it drops, either through an air gap (the small chrome cap on the sink deck) or as a high loop fastened under the counter. This page explains how each one works, what each protects against, what your local code may require and how to tell when one has failed. For other dishwasher problems, start at our dishwasher troubleshooting guide.

Which one do you have? A 30-second check

  1. Look behind the faucet. A short chrome or colored cylinder on the sink deck or countertop is an air gap. GE describes it as part of the plumbing, not part of the dishwasher.
  2. No cap? Open the sink cabinet. Follow the drain hose from the side wall toward the disposal or the sink tailpiece. If it climbs and is clipped or strapped to the underside of the counter before it drops, you have a high loop.
  3. Neither? If the hose lies on the cabinet floor and runs straight into the disposal or tailpiece, you have no protection at that point. Whirlpool's service manual checks two things here: a drain loop attached to the side of the dishwasher, and a drain connection at least 20 inches off the floor.

The parts and what each one does

Seven parts sit between the dishwasher's sump and the house drain. The last two columns are the useful ones when something goes wrong: how each part usually fails, and what you see when it does.

PartIts jobHow it usually failsWhat you notice
Drain pump and check valvePushes water out of the sump; the check valve lets it out but not back inCheck valve sticks open or blockedDirty water or film in the tub; slow draining
Drain hose (inlet side)Carries water from the dishwasher to the air gap or loop, typically 5/8 inchKinked, crushed by the dishwasher, cloggedWater left in the tub; drain error code
Air gap body and capGives the water an open break above the sink's flood levelFood and grease build up insideWater spitting from the air gap onto the sink or counter; a sour smell
Outlet hoseCarries water from the air gap down to the drain, typically 7/8 inchClogs where it enters the disposal or tailpieceAir gap overflows even after you clean the cap
High loop fastenerHolds the hose up under the counterClip or strap lets go; hose sagsSink water in the tub; water draining out during the fill
Disposal inlet or tailpiece wyeWhere the dishwasher hose joins the sink drainKnockout plug left in a new disposal; food clogDishwasher never drains after a disposal install
Sink trap and drain lineCarry the water to the house drainClog below the dishwasher connectionSink and dishwasher both back up

Hose sizes are the common ones that Ferguson, a plumbing supplier, lists; GE's installation instructions say its molded hose end fits inlet ports from 5/8 to 1 inch. The sink side of this path, including the trap, is covered on our P-trap and drain venting page.

How the drain water travels, step by step

Dishwasher With an air gap Air gapon the sink deck or counter FL mark Flood level rim Outlet hosetypically 7/8 inch Inlet hosetypically 5/8 inch Disposal Dishwasher With a high loop High loopfastened underthe counter Disposal
Left: the inlet hose carries the water up to the air gap, which gives it an open break above the sink's flood level rim, and a second, larger hose carries it down to the disposal or tailpiece. Right: a high loop has no break; one hose rises to the underside of the counter, fastened there, before it drops. Schematic, not to scale.
  1. The pump starts. Dirty water collects in the sump under the filter, and the drain pump pushes it out through the check valve into the drain hose.
  2. The water climbs. Pump pressure lifts it up the hose to the highest point of the run: the air gap's inlet, or the top of the high loop.
  3. Air gap only: the break. In an air gap, Sears Home Services explains, the inlet hose brings the water up from the dishwasher and an outlet hose carries it on to the sink drain or disposal. Between the two, the water crosses a short physical gap, which is what makes it a real break rather than a continuous hose.
  4. The water falls. From the peak, gravity takes over. The water runs down the outlet hose, or down the far side of the loop, into the disposal's dishwasher inlet or the wye on the sink tailpiece.
  5. The pump stops. The check valve keeps water in the hose from running back into the tub, and the height of the loop or the break in the air gap keeps sink water from following it.

The two things they prevent: backflow and siphoning

Most explanations stop at "it keeps dirty water out." There are two separate failures, and they show up as different symptoms, which is why it helps to know both.

Backflow from the sink or disposal

When the sink drain clogs, water rises in the disposal and the tailpiece. If the dishwasher hose connects there with no rise, that water has a level path into the tub. Samsung lists a missing air gap or high loop as the next most common drain problem after a dishwasher pinching its own hose, and says that without one water may flow back into the dishwasher.

The two methods handle a clog differently. An air gap gives the backed-up water somewhere else to go: GE says it prevents water from a clogged drain from backing up into the dishwasher, and that is why a blocked air gap spits water out of the fitting onto the sink or counter instead. A high loop only makes the water climb. Ferguson notes that if the sink floods above the loop's highest point, back-siphonage can still happen, and that a sagging hose loses the protection. That is the core of the "air gap versus high loop" argument. The International Code Council calls an air gap, a vertical separation, the best way to prevent backflow on drinking-water connections, and air gap maker AirGap International goes further, writing that a high loop does not do the same job because the continuous hose can still let water siphon back. Treat that last claim as a manufacturer's view.

Siphoning the tub empty

The second job is less known. If the end of the drain hose sits lower than the water in the tub, water that enters the hose can keep running downhill on its own and pull the tub empty while the dishwasher is trying to fill or wash. GE's rule targets exactly that.

18 inches GE requires an air gap when the waste tee or disposal connection is less than 18 inches above the floor, to prevent siphoning.

Source: GE Appliances, Built-In Dishwasher Installation Instructions, Pub. No. 31-30576

Whirlpool's service manual for its 18- and 24-inch ADA built-ins has a test for it. Let the dishwasher finish a normal fill, press Cancel/Drain for 5 to 10 seconds, then open the door. The water should stay in the tub. If it keeps draining away, the manual says to confirm the drain loop is attached to the side of the dishwasher and that the hose connects to a drain at least 20 inches off the floor. Whirlpool files this under "will not fill or low water", so the first sign is a tub that never seems full, not a flood.

How high is high enough? The makers' numbers

Every maker publishes a minimum, and some publish a maximum, because the pump has to lift the water to the peak. LG lists a hose that is "too high" next to kinked and too long among the causes of its OE drain code. Measure with a tape from the floor to the top of the loop or to the drain connection, and compare it with your own model's instructions.

BrandMinimum heightMaximum heightHose length limitAir gap needed when
WhirlpoolLoop at least 20 in from the floorNot stated on that pageNot stated on that pageConnection below 20 in from the floor
GELoop at least 32 in above the floorNot stated10 ft totalLocal code requires it, or the connection is under 18 in
BoschPart of the hose at least 33 in off the floor43 in150 in, including the hose to the air gapLocal ordinance requires it
LGHose end at least 12 in above the dishwasher base (not the floor)40 in above the base12 ft, no extensionNot stated on that page
SamsungPart of the hose above the sink connectionNot statedNot statedLocal regulation decides

Sources: Whirlpool's drain loop page, GE's installation instructions, Bosch installation instructions 9002059336, LG's OE code page and Samsung's drain page. Whirlpool's 20 inches is a floor that GE's and Bosch's numbers sit well above, so a loop that suits a Whirlpool may be too low when you swap in a GE or a Bosch. Recheck the height whenever the dishwasher, the disposal or the sink changes. Too long or too high a hose is a drain problem too; if water is staying in the tub, our page on a dishwasher not draining walks through the full drain path.

What the plumbing code says

Whether a high loop is allowed depends on which model code your state or city adopted, and on local amendments. The manuals defer to it: Bosch says to install an air gap if local ordinance requires one, and GE says not all areas require one.

Code or placeWhat it accepts
North Carolina State Fire Marshal interpretation of Section 802.1.6, 2012 NC Plumbing CodeA deck-mounted air gap, or a waste line that rises and is securely fastened to the underside of the sink rim or counter
Minnesota (rule 4714.0807, which amends Uniform Plumbing Code Section 807.3)An approved air gap fitting, or the discharge line run as high as possible under the countertop and securely fastened; a listed air gap goes in with its flood level (FL) mark at or above the flood level of the sink or drainboard
Seattle and King County, WashingtonAn air gap fitting for all domestic dishwashers
CaliforniaA physical air gap above the counter, according to Ferguson's summary of the California Plumbing Code

Sources: North Carolina Office of State Fire Marshal interpretation, Minnesota Rules 4714.0807, Public Health – Seattle & King County.

The debate is real among code officials. A request filed with the Minnesota Plumbing Board argued that required air gaps add cost and have caused water damage when they fail, and that the submitter found no record of a sink backup forcing waste water into a dishwasher and causing illness. That is one submitter's argument, not a study. The practical answer for a homeowner is simpler: call your local building department and ask which method it accepts before you remove an air gap or replace a dishwasher.

When it goes wrong: symptoms, tests and fixes

The order follows how often each problem shows up and how cheap the test is. Before you disconnect any hose, unplug the dishwasher or switch off its circuit breaker, and keep a towel and a shallow pan under the connection.

What you seeLikely causeThe testFix or partDIY or pro
Water spits out of the air gap cap while the dishwasher drainsFood and grease inside the air gapLift off the cover and unscrew the plastic cap; look for buildupClean it ($0)DIY
Air gap still overflows after cleaningClog in the outlet hose, the disposal inlet or the tailpiece wyeRun the disposal; check the hose end where it meets the disposal or wyeClear the hose end; knock out a disposal plug if it is newDIY; plumber if the sink drain itself is blocked
Tub never seems full (low water)Siphoning: connection too low or loop detachedWhirlpool's fill, drain 5–10 s, open-door checkRaise and fasten the loop, or add an air gapDIY for the loop; air gap may need a new hole
Gray water or film in the tub after it sitsBackflow: sagging or missing loop, or a check valve that does not sealLook at the loop; do Whirlpool's check-valve fill testRefasten the loop; replace the drain hose and check valve ($53.99 to $70.10)DIY
Sour smell at the sink capFood residue in the air gapRemove the cap and look insideBrush it cleanDIY
Dishwasher and sink both back upClog below the dishwasher connectionFill the sink and watch it drainClear the sink drainDIY first, then a plumber

Cleaning a clogged air gap

GE's steps: lift the chrome cover straight up, unscrew the plastic cap, remove whatever has built up and rinse the cap, then check the hose from the air gap to the sink drain or disposal. Family Handyman adds a bottle brush soaked in household cleaner, plunged up and down inside the body, and says that if water still comes out, clean the line where it meets the disposal or wye. A sink that is slow on its own points below that; see kitchen sink not draining or, if you have a disposal, sink clogged through the disposal.

Fixing a sagging or missing high loop

Lift the hose to the height your installation instructions give and fasten it to the underside of the countertop, as GE's Method 2 shows, with a clip or strap that will not crush the hose. Keep the hose free of kinks on the way up and down. If the dishwasher hose connects to the disposal or tailpiece below 18 inches and you have a GE, or below 20 inches with a Whirlpool, a loop is not enough by the makers' rules and you need an air gap.

Testing the check valve

Whirlpool's service manual lists a drain loop check valve that does not seal as a cause of film on dishes and of water left in the unit. Its test: with the dishwasher unplugged, disconnect the drain hose at the plumbing connection, hold the hose up above the dishwasher and fill it with water. If water runs into the dishwasher, the manual says to replace the entire drain loop and install it as high as possible, fastened to the underside of the countertop if you can.

Parts and costs (checked November 2026)

An air gap is a cheap part. Adding one where none exists may also need a new hole in the sink deck or counter, as Ferguson notes. Confirm every part number against your model before ordering.

ItemPrice, Sears PartsDirectPrice, iFixitPro cost (HomeAdvisor)
Whirlpool air gap kit WP300096$39.05$33.99 (out of stock)Plumber $45 to $200 an hour; most jobs $182 to $501
Whirlpool drain hose with check valve WPW10358302$70.10$53.99$50 to $100 for a drain hose replacement
Fasten an existing loop under the counterA clip or strap——
Air gap added during a dishwasher install——Install labor $150 to $300; an air gap is an extra plumbing cost

Prices from Sears PartsDirect and iFixit, checked November 2026. Pro costs from HomeAdvisor's plumber, dishwasher repair and dishwasher installation cost guides, updated June 2026.

Stop and call a pro if

  • The sink, the disposal and the dishwasher all back up after you have cleaned the air gap and the hose end, or other drains in the house gurgle. The clog is in the drain line, which is a plumber's job.
  • Adding an air gap means drilling a new hole through a stone or quartz countertop.
  • Water is on the floor in front of or under the dishwasher, not just in the sink cabinet. See dishwasher leaking.
  • Gray water with a sewer smell keeps coming into the tub even with a fastened loop or a clean air gap.
  • You smell burning, or see scorched or melted wires at the dishwasher's electrical box behind the lower front panel. Leave the breaker off and call an appliance technician.

FAQ

Do I need a dishwasher air gap if I have a high loop?

It depends on your local code. North Carolina's State Fire Marshal, interpreting Section 802.1.6 of the 2012 NC Plumbing Code, accepts either one; Seattle and King County require an air gap for every domestic dishwasher. GE also requires an air gap when the drain connection is under 18 inches.

Is a high loop as good as an air gap?

Not quite. A high loop has no physical break, so if the sink floods above the loop's highest point, back-siphonage can still happen, according to Ferguson. An air gap gives the water an open path out of the cap instead.

Why is water coming out of my dishwasher air gap?

Something below it is blocked: usually food and grease inside the air gap, then the hose end at the disposal or wye. Clean the cap first, then the hose end.

How high should a dishwasher drain loop be?

Use your dishwasher's number: at least 20 inches for Whirlpool, 32 for GE and 33 for Bosch, measured from the floor. Bosch caps the hose height at 43 inches, and LG puts the hose end no higher than 40 inches above the dishwasher base.

Can I remove my air gap and use a high loop?

Only where your local code allows it and your dishwasher's instructions do. Ask your building department first; some places, such as King County, require the air gap.

Next step: open the sink cabinet with a tape measure and check where your hose peaks. If you need the rest of the dishwasher picture, the dishwasher troubleshooting guide starts from the symptom, and dishwasher smells covers odors that do not come from the drain.

Sources

  1. GE Appliances, Built-In Dishwasher Installation Instructions, Pub. No. 31-30576
  2. GE Appliances, Dishwasher - Water in the Bottom of the Tub
  3. GE Appliances, Dishwasher - Cleaning the Air Gap
  4. Whirlpool Product Help, Checking the Drain Loop Height
  5. Whirlpool Corporation, Service Manual: 18" & 24" ADA Built-In Dishwashers, W11187658
  6. Bosch, Dishwasher Installation Instructions 9002059336
  7. LG US, LG Dishwashers - Troubleshooting an OE Error Code
  8. Samsung US, Samsung Dishwasher Is Not Draining
  9. North Carolina Office of State Fire Marshal, Domestic Dishwasher Waste Connection (2012 NC Plumbing Code interpretation)
  10. Minnesota Revisor of Statutes, Minnesota Rules 4714.0807
  11. Minnesota Plumbing Board, Request for Action PB0099
  12. Public Health – Seattle & King County, Domestic Dishwasher Connections
  13. International Code Council, Plumbing Code Essentials (2018 IPC), Backflow Protection, pp. 124-125
  14. Ferguson, High Loop vs. Air Gap Backflow Prevention for Dishwashers
  15. AirGap International, AG200-004 Dual Air Gap Submittal Sheet
  16. Family Handyman, What to Do When Water Is Coming Out of Your Dishwasher Air Gap
  17. Sears Home Services, How Does a Dishwasher Air Gap Work?
  18. Sears PartsDirect, Dishwasher Air Gap Kit WP300096
  19. iFixit, Whirlpool Gap-Air WP300096
  20. Sears PartsDirect, Dishwasher Drain Hose and Check Valve WPW10358302
  21. iFixit, Whirlpool Dishwasher Drain Hose WPW10358302
  22. HomeAdvisor, How Much Does Dishwasher Repair Cost? (updated June 17, 2026)
  23. HomeAdvisor, How Much Does a Plumber Cost? (updated June 19, 2026)
  24. HomeAdvisor, How Much Does Dishwasher Installation Cost? (updated June 17, 2026)