Dryer Not Heating? 9 Causes, Cheapest Check First, With Meter Readings
In short
A dryer not heating while the drum still turns usually has a no-heat setting, a lost power or gas supply, or one open part in the heat circuit. Check the cycle and both breakers first: Whirlpool says an electric dryer runs on two, and one can trip while the drum keeps turning. Unplugged, the electric heat circuit on a Whirlpool tech sheet reads about 10 ohms. The usual parts cost about $15 to $55 (checked November 2026). Checked against Whirlpool, GE and Samsung support pages and Whirlpool service tech sheets.
Cool, damp towels after a full cycle, with the drum turning and the motor humming the whole time, tell you the motor circuit works, so the fault is in the part that makes heat: a chain of parts wired in series on an electric dryer, a burner and its ignition parts on a gas one. One open link gives the same cold drum, which is why guessing at parts gets expensive. The checks below run cheapest first, with readings from Whirlpool service tech sheets. For other symptoms, such as a dryer that won't start, use the dryer troubleshooting guide.
Quick checks first (free, about 10 minutes)
- Prove it. Whirlpool's test: pick a heated timed cycle, run the dryer empty for five minutes, then open the door and feel inside. Samsung's is shorter: Time Dry with Eco Dry off, and feel for heat after 30 seconds. Warm air but loads that take forever is an airflow problem, covered in dryer vent cleaning. A cold drum is this page.
- Read the cycle name. Whirlpool's Air Only and Air/Fluff Only cycles add no heat at any point, and GE says the cycle should be a dry cycle, not fluff or cool-down.
- Cycle both breakers (electric). Push each handle fully to off, then back on. GE warns that a breaker can be partly tripped without looking tripped; Samsung says to leave it off for 30 seconds.
- Look at the gas valve (gas). Whirlpool says the drum will turn but the dryer won't heat with the shutoff valve closed, and the valve is open when its handle runs parallel to the gas pipe. On a new installation, GE says to confirm the gas has been turned on at all.
- Listen (gas). GE lists the normal sounds of a working burner: a buzz as the solenoid valve opens, clicks at the start of the heat cycle and at ignition, and a low roar from the flame. Bosch's service manual says its igniters glow after 30 seconds, and the gas flows only once the hot igniter has opened the flame sensor, so give it a minute or two. A roar means the burner lit. No roar after a couple of minutes on a heated cycle means it probably didn't.
If you smell gas at any point, stop: leave the house and call the gas utility or 911 from outside.
Why a dryer stops heating: 9 causes in order
The order is our editorial judgement from the manufacturer documents in Sources, weighted by how often each cause comes up and how cheap its test is, not a measured frequency. Every meter test is done with the dryer unplugged and the wires pulled off the part.
| Cause | How common | The test | What you will see | Fix or part | DIY or pro |
|---|---|---|---|---|---|
| 1. No-heat cycle or eco setting | Common, free to rule out | Heated Timed Dry, eco mode off | Heat within the first minutes | Change the setting | DIY |
| 2. Power: one breaker of the pair tripped, or only 120 volts at an electric dryer | Common | Cycle both breakers; an electrician measures the outlet | Heat returns after the reset, or the outlet lacks 208 or 240 volts | Breaker reset, or circuit or cord repair | DIY reset; electrician for the circuit |
| 3. Gas shutoff valve closed | Mostly after a move or new install | Look at the handle | Handle across the pipe instead of along it | Turn it parallel to the pipe | DIY |
| 4. Blocked exhaust tripping the heat limits | Common | Lint screen, outside hood flap, vent warning codes | Heat that cuts out early, or a limit part that later tests open | Clean the vent before replacing any part | DIY; pro for duct inside walls |
| 5. Thermal cut-off or high limit open | Common after airflow trouble | Continuity across each part | Open circuit on either one | Replace both (kit 279816 on many Whirlpool-built models) | DIY |
| 6. Heating element open (electric) | Common on electric | Ohms through the heat circuit, then the element | Open instead of about 10 ohms | Element (279838 on many Whirlpool-built models) | DIY |
| 7. Thermal fuse open (gas) | Common on Whirlpool-built gas models | Continuity across the fuse | Open circuit | New fuse, after fixing the cause | DIY |
| 8. Igniter or gas valve coils (gas) | Common on gas | Technician reads the igniter (rated 50 to 500) and each coil | Silent burner, or an igniter that glows with no flame | Igniter or coil kit | Pro |
| 9. Thermistor, centrifugal switch, heater relay or control | Less common | Thermistor kΩ against the temperature table; the rest by technician | Reading outside the table, or every part tests good | Thermistor, motor or control | DIY thermistor; pro for the rest |
Power: two breakers and the 120-volt trap
An electric dryer splits its load. Whirlpool describes two breakers, one running the motor and drum and the other the heating element, so a single trip leaves you with a dryer that tumbles cold. GE says the same dryer "may run with a partial voltage of 120 volts" but won't heat without its 208- or 240-volt supply, and Samsung notes that on low voltage the panel and motor work while the heater doesn't.
If a full off-and-on cycle of both breakers doesn't bring the heat back, the outlet or circuit needs measuring, and Whirlpool says to check with a qualified electrician. What you can do is look. Unplug the dryer, take off the small cover over the cord connection on the back, and check the terminal block. GE lists burnt, broken, frayed or loose connections there as a cause; Whirlpool says to make sure the terminal screws are tight. A scorched terminal block is a stop sign, not a tightening job: the stop box below covers it.
A gas dryer has no such split. GE says it needs its own dedicated 120-volt outlet, and the gas does the heating.
Airflow: how a clogged vent ends in a cold dryer
Lint rarely stops the heat directly; it trips the parts that guard the heater. When air moves slowly, the heater housing runs hotter than it should. A high-limit thermostat there opens and shuts off the heat; on the Kenmore electric model in a Whirlpool tech sheet it opens at about 250°F. If the housing keeps climbing, a one-shot thermal cut-off opens (352°F on that Kenmore diagram) and the heat stays off until someone replaces it. That is why Whirlpool's instruction for an open cut-off is to replace the cut-off and high limit, then "check for blocked or improper exhaust system."
So treat a dead limit part as evidence, not as the fault. Clean the lint screen, check that the outside hood flap opens while the dryer runs, and look behind the dryer for a crushed duct. Some dryers tell you: Samsung's vent test codes C80, C90, CLg and Cg mean a clog, and LG's d90 and d95 codes mean the dryer has detected a 90% or 95% blockage. LG says not to use the dryer until the exhaust has been cleaned and repaired. Full duct cleaning is in dryer vent cleaning.
Thermal cut-off and high-limit thermostat
On the Whirlpool model in tech sheet W10286852 both thermal parts are reached through the toe panel, and both read closed when good. The high limit is a thermostat that opens when the housing overheats. The cut-off is the backup: Whirlpool's gas tech sheet 8533776 marks its 352°F cut-off "nonresettable," and once open it has to be replaced. Sears PartsDirect sells Whirlpool's kit 279816 with a 309°F cut-off, a different rating from those diagrams, so ratings vary by model and the part number has to match yours.
- Unplug the dryer. On the Whirlpool model in tech sheet W10286852, the thermal parts are reached from the front through the toe panel.
- Pull the wires off each part and check continuity across its two terminals. A good part shows continuity; an open one doesn't.
- If either one is open, Whirlpool says to replace both the cut-off and the high-limit thermostat, then check the exhaust and the element.
Never bypass or jumper a cut-off, high limit or thermal fuse to get heat back. They are there to cut the heat when the dryer overheats, and the U.S. Fire Administration reports that failure to clean was the leading factor in home clothes dryer fires from 2018 to 2020, at 31%.
Heating element (electric dryers)
The element is a coil of resistance wire inside the heater housing. Current through the coil heats the air the blower pulls past it. When the wire breaks, the element reads open.
Whirlpool's tech sheet tests the whole electric heat path in one reading: with the dryer unplugged, measure from the red wire terminal at the thermal cut-off to the red wire terminal at the heater.
About 10 ohms is a good reading across the thermal cut-off, high-limit thermostat and heater together on Whirlpool's electric dryer test. An open circuit means one of the three has failed.
Source: Whirlpool, Tech Sheet W10286852
If the path reads open and the cut-off and high limit both show continuity, the element is the open part. The Kenmore diagram gives 7.8 to 11.8 ohms for its element, and its test adds a second check: the element "should be open to ground, chassis, and neutral." A reading from the element to the cabinet means it is shorted to the chassis: replace it. When an element fails this way, it can take a thermal fuse with it: Kenmore's sheet lists a shorted heat element among the causes to check after the fuse opens.
Thermal fuse: no heat on gas, no start on electric
The same small part causes different symptoms depending on the fuel. On Whirlpool tech sheet W10286852, the thermal fuse on the electric dryer is wired in series with the drive motor, while on the gas dryer it is wired in series with the gas valve. So on these Whirlpool-built models:
- Electric: a blown fuse stops the motor, so the dryer won't start at all. If your drum turns, the electric thermal fuse isn't why it's cold.
- Gas: a blown fuse cuts power to the gas valve, so the drum turns and the burner never lights. The fuse is one of the first parts to test.
Test it unplugged, for continuity across its two terminals. Whirlpool's gas tech sheet 8533776 rates the fuse at 196°F; once open, it is replaced, not reset. Other brands wire the fuse differently (Samsung's quirks are on Samsung dryer not heating), so check the wiring diagram on your own dryer before you order. After a fuse opens, Kenmore's tech sheet says to check for a failed thermistor, a shorted heat element or other causes. Rule out a blocked vent first, as above.
Gas burner: igniter, flame sensor and valve coils
A gas dryer lights itself in stages. Bosch's service manual describes it: with the flame sensor cool and closed, the igniter and the valve's holding and booster coils switch on. The igniter heats up, the hot sensor opens, the secondary coil switches on and gas flows. If the flame goes out, the sensor notices within 30 to 60 seconds and restarts the igniter.
That sequence tells a technician where to look. An igniter that never glows points to the igniter or the circuit feeding it. An igniter that glows with no flame following points to the next steps in the sequence: the sensor or the coils. The readings they work from:
| Part | Reading (dryer unplugged) | Source |
|---|---|---|
| Igniter | Rated 50 to 500 | Whirlpool tech sheet 8533776, gas wiring diagram |
| Valve coil, terminals 1 to 2 | 1,365 ohms ±25 | Whirlpool tech sheets W10286852 and 8533776 |
| Valve coil, terminals 1 to 3 | 560 ohms ±25 | Same |
| Valve coil, terminals 4 to 5 | 1,220 ohms ±50 | Same |
| High-limit thermostat (gas) | Continuity across its red and blue wires | Whirlpool tech sheet W10286852 |
These are for following a technician's diagnosis, not a do-it-yourself job: the igniter and coils mount on the burner and gas valve assembly, and under our safety policy we don't give steps for work on the gas train. Your part of a gas no-heat call ends at the cycle, the outlet, the breaker, the shutoff valve handle, the listen test, and, with the dryer unplugged, continuity tests on the thermal fuse and cut-off if you are comfortable with a meter.
Temperature control: thermistor, centrifugal switch and control board
When every part in the heat chain reads good, the fault is in what switches it on.
Exhaust thermistor. It tells the control how hot the exhaust is. On W10286852 the dryer flashes F3E1 when the thermistor is open and F3E2 when it is shorted. Unplugged, compare its resistance with the tech sheet's table: 11.5 to 13.5 kΩ at 70°F, 8.5 to 10.5 kΩ at 80°F, 6.8 to 8.8 kΩ at 90°F. Whirlpool's instruction: if the reading doesn't agree with the table, replace the thermistor. Some dryers use an operating thermostat in this spot instead; the Kenmore sheet notes its thermistor is used "in place of an operating thermostat."
Centrifugal switch. It is part of the drive motor, and Kenmore's tech sheet notes that it "also opens heater circuit," so a motor fault can show up as no heat. Testing it is technician work.
Heater relay and control board. On electronic models the control switches the heat through a relay. On the gas side of Whirlpool's W10286852 test sequence, the step after the valve coils check out is replacing the control electronics. Before any of that, the sheet says to look at the connections, because corrosion on them is a potential cause of a control not working.
Heat present but weak? The same tech sheet gives a test that needs no meter. Run an empty dryer with a clean lint screen on Timed Dry and hold a glass bulb thermometer in the center of the exhaust outlet. The heat should shut off at about 155°F on High, 140°F on Medium and 125°F on Low (each ±5°F) and come back on 10 to 15°F lower. The reading can overshoot by up to 30°F. GE's outlet set points differ (125°F low, 135°F medium and high), so use your own brand's numbers.
Model and brand differences
| Brand | Heat test | Power or fuel point | Worth knowing |
|---|---|---|---|
| Whirlpool (and Kenmore models built by Whirlpool) | Heated timed cycle, empty, 5 minutes | Two breakers on electric; gas valve handle parallel to the pipe | Thermal fuse stops the motor on electric, the gas valve on gas (W10286852) |
| GE Appliances | A dry cycle, not fluff or cool-down | Can run on partial 120 volts with no heat; breaker may be partly tripped | Outlet set points 125°F low, 135°F medium and high |
| Samsung | Time Dry, Eco Dry off, feel after 30 seconds | Two circuits; breaker off 30 seconds | Vent test codes C80, C90, CLg or Cg mean a clog; see Samsung dryer not heating |
What it costs (checked November 2026)
We checked genuine Whirlpool part numbers on November 23, 2026. They fit many Whirlpool-built dryers, not all; confirm yours before ordering.
| Part | Fixes | Sears PartsDirect | Second retailer |
|---|---|---|---|
| Heating element 279838 | Electric, element reads open | $50.54 | $52.99 (iFixit) |
| Thermal cut-off kit 279816 (cut-off and high limit) | Cut-off or high limit reads open | $54.05 | No second listing we could load |
| Thermal fuse WP3392519 | Gas, fuse reads open | $42.30 | $14.99 (iFixit) |
| Igniter kit 279311 | Gas, igniter out of range | $28.26 | $30.95 (Home Depot) |
| Valve coil kit 279834 | Gas, coil out of range | $26.08 | $23.54 (FiltersFast) |
For a pro, HomeAdvisor (updated June 17, 2026) puts a no-heat repair at $80 to $420, with a service fee of $50 to $80 on top. HomeGuide (updated November 2024) breaks it down by part: $150 to $350 to replace a heating element, $75 to $150 for a thermal fuse, $100 to $300 for a thermostat, $100 to $250 for an igniter, $100 to $200 for a coil and $250 to $500 for a control board. That gap is the case for testing first: an element at $50.54 against $150 to $350 installed, if the meter says the element failed.
Stop and call a pro if
- You smell gas. Leave the house and call the gas utility or 911 from outside; don't use switches, phones or anything that sparks near the leak.
- The dryer's breaker trips again as soon as you reset it, or the cord or terminal block is scorched or melted.
- Both breakers are on and the dryer still runs cold: the outlet needs a live voltage test by an electrician.
- A new thermal fuse or cut-off opens again within a few loads, even after the vent was cleaned.
- The fault is in the igniter, flame sensor, valve coils or anything else on the gas burner assembly.
- Vent warning codes or weak airflow persist after you clean what you can reach: the duct inside the wall needs a vent cleaning service.
Dryer not heating: common questions
Why is my dryer running but not heating?
Because the heat has its own circuit. On an electric dryer, check that neither of the two breakers has tripped and that the cycle isn't an air-only one, then test the cut-off, high limit and element unplugged. On a gas dryer, check the shutoff valve handle, then the thermal fuse.
Can a clogged dryer vent stop the heat?
Indirectly. Restricted airflow makes heat build up until a safety device (the high limit or the thermal cut-off) trips. Whirlpool's tech sheet sends you to the exhaust whenever the cut-off is found open.
Is there a reset button for the heat?
Some do: Bosch's WTVC gas dryer has a hi-limit protector reset by a red button. The thermal fuse and thermal cut-off can't be reset: once open, they have to be replaced. Cycling the breaker, as Whirlpool and Samsung suggest, restores lost power, not a blown part.
How long should a dryer take to get hot?
Samsung's heat test checks after 30 seconds and Whirlpool's after five minutes, so a working dryer should feel warm within the first few minutes. On a gas model, Bosch's igniters glow after about 30 seconds, before the gas flows.
Still stuck, or seeing a different symptom? A drum that won't turn is covered in dryer drum not turning, and new squeals or thumps in dryer making noise. How we choose and date sources is in our editorial policy.
Sources
- Whirlpool, Not Heating – Electric Dryer
- Whirlpool, Not Heating – Gas Dryer
- Whirlpool, Tech Sheet W10286852 Rev B, electric and gas dryer (PDF)
- Whirlpool, Tech Sheet 8533776, gas dryer (PDF)
- Whirlpool, Tech Sheet 3979705, Kenmore electric dryer (PDF)
- GE Appliances, Electric Dryer - Runs But Does Not Heat
- GE Appliances, Gas Dryer - Runs But Does Not Heat
- GE Appliances, Dryer Squeaking and Abnormal Noises
- GE Appliances, Dryer Temperatures During Cycles
- Samsung US, Dryer Is Not Heating
- LG Electronics US, Understanding d90 and d95 Error Codes
- Bosch, WTVC gas dryer service manual, section 4: Components (PDF)
- U.S. Fire Administration (FEMA), Appliance and Electrical Fire Prevention
- Public Service Commission of Wisconsin, Natural Gas Consumer Safety
- HomeAdvisor, How Much Does It Cost to Repair a Dryer? (updated June 17, 2026)
- HomeGuide, How Much Does Dryer Repair Cost? (updated November 14, 2024)
- Sears PartsDirect, Whirlpool Dryer Heating Element 279838
- iFixit, Whirlpool Dryer Heating Element 279838
- Sears PartsDirect, Whirlpool Dryer Thermal Cut-Off Fuse Kit 279816
- Sears PartsDirect, Whirlpool Dryer Thermal Fuse WP3392519
- iFixit, Whirlpool Dryer Thermal Fuse WP3392519
- Sears PartsDirect, Whirlpool Dryer Burner Igniter Kit 279311
- Home Depot Appliance Parts, Igniter Kit 279311
- Sears PartsDirect, Whirlpool Dryer Valve Coil Kit 279834
- FiltersFast, Whirlpool 279834 Gas Valve Solenoid