Refrigerator Compressor Not Running? Rule Out Defrost, Relay and Board Before the Compressor
In short
A refrigerator compressor not running is often doing its job: Whirlpool says the refrigerator regularly runs an automatic defrost cycle and to recheck in 45 minutes, and a standard compressor can be off most of the time in a cool room. If it stays silent while the cabinet warms, force it on in service mode, then test the start relay (about $51 to $55, checked November 2026) before blaming the compressor. Checked against Whirlpool, Frigidaire and GE documents and Tecumseh's service handbook.
A silent compressor does not usually mean the refrigerator is finished. On the Sears Home Services page for compressor-not-running repairs, the compressor itself is the failed part 41% of the time and the electronic control board 30%; the evaporator accounts for 8% and other parts for 21%. Several causes that stop a compressor cost nothing to fix: a defrost cycle, a display mode, a tripped outlet, or a normal off cycle.
In Penn State's energy course, the compressor squeezes refrigerant gas so its pressure and temperature rise, and the condenser coils shed that heat. The parts around it (start relay, overload, temperature sensor, control board) decide whether it gets power. Those you can test; the sealed system is technician work.
First, is it really not running?
Listen and look at the bottom back. Sears Home Services says the compressor shares a circuit with the condenser fan motor on most refrigerators, so a fan spinning behind the lower rear cover means the compressor circuit has power.
Know how long it should be off. A standard compressor cycles. Frigidaire's service data sheet A01511101 for one top-freezer family gives an operating time of 25 to 35% in a 65°F room and 45 to 55% at 90°F, measured with no food load and no door openings. Variable-speed compressors differ: Frigidaire says many of its French-door models use compressors designed to run continuously except during defrost.
Read a thermometer. The FDA's limits are 40°F or below in the fridge and 0°F in the freezer. Silent at 38°F is an off cycle; silent at 50°F is a fault. If the compressor does run but the cabinet stays warm, the cause is elsewhere: start with refrigerator not cooling.
Quick checks first (free, up to an hour)
1. Wait out a defrost cycle
A frost-free refrigerator switches the compressor off on purpose while a heater melts frost off the evaporator coil. Whirlpool tells owners to recheck in 45 minutes. One Frigidaire side-by-side sheet runs a 24-minute defrost every 6 to 96 hours of compressor run time. GE Appliances lists hissing or sizzling from water on the defrost heater as a normal sound.
2. Check the power path
Whirlpool's list: test the outlet with a lamp, check the breaker and any GFCI outlet, and use no extension cord and no switched outlet on a grounded 115-volt, 15- or 20-amp circuit. If a breaker or GFCI has tripped, Whirlpool says to reset it. If it trips again when the refrigerator tries to start, leave it off. The Tecumseh service handbook calls a tripped breaker a strong indication of a ground fault in the compressor
3. Look for a mode, or cooling switched off
- Whirlpool: in Showroom mode the interior lights turn on but neither section cools, and some models show "Showroom" on the display. Some need turning back on after a power outage or surge.
- Samsung: Cooling Off mode shows OF OF, O FF, OFF OFF or scrolling bars; it will not cool in this mode.
- LG: a display reading O F F means demo mode.
- GE Appliances: just serviced, it may still be in diagnostic mode; disconnect power for 30 seconds.
- Dial models: check the dial is not off. HomeGuide suggests turning the thermostat from the lowest to the highest setting; if you hear no click, the thermostat might have failed.
4. Give it time to restart
GE says clicking after a power outage is the compressor trying to restart, and it can last 3 to 5 minutes. After a power cycle, Samsung allows about three hours to see the temperature drop. A newly installed refrigerator needs about 24 hours to cool down, according to both Whirlpool and GE.
5. Let an overheated compressor cool down
An overheated compressor switches off until it cools. Whirlpool's tech sheet W10480705 lists an overload that opens at 221°F (±9°F) and closes again at 142°F (±16°F). Tecumseh warns that an internal thermal protector may take as long as an hour to reset. GE says a refrigerator may not cool properly below 60°F or above 110°F, wants at least 1 inch of clearance on each side, top and back, and says dirty condenser coils make the sealed system less efficient (most GE models made since 2001 need no coil cleaning; compact and smaller top-freezer models do). If the condenser fan at the bottom back has stopped or rattles, refrigerator making noise covers that fan.
Refrigerator compressor not running: causes, cheapest test first
Ordered by cost of the test: free checks, then a multimeter, then a technician. Percentages are Sears Home Services' repair shares.
| Cause | How common | The test | What you will see | Fix or part | DIY or pro |
|---|---|---|---|---|---|
| Normal off cycle or defrost | Every day | Thermometer; recheck in 45 minutes | Fridge at 40°F or below; compressor restarts | Nothing | None needed |
| Mode on, or cooling switched off | Rule out first | Read the display; power off 30 seconds (GE) or 2 minutes (Samsung) | "Showroom", OF OF or O F F; lights on, no cooling | Exit the mode (owner's manual) | DIY |
| No power at the outlet | Rule out first | Lamp in the outlet; breaker and GFCI | Dead outlet or tripped breaker | Reset once; electrician if it keeps tripping | DIY, then pro |
| Overheated, overload open | Check when coils are dusty or the room is hot | Look at coils and condenser fan; wait up to an hour | Silent, then restarts after cooling | Clean coils; condenser fan motor | DIY or pro |
| Temperature sensor (thermistor) or cold control | Check before parts | Service mode forces the compressor on | Runs in test, not in normal mode | Sensor; Whirlpool lists 2,700 ohms at 77°F | DIY |
| Start relay and overload | Check before the compressor | Unplugged: shake it, then continuity | Rattle or open circuit; repeated clicks | W10613606, about $51 to $55 | DIY |
| Control board or wiring | 30% (Sears) | Condenser fan off too; continuity through the compressor circuit | Circuit reads about 5 ohms but gets no power | Board, about $400 to $750 to replace (HomeGuide, 2023) | Pro for live tests |
| Compressor | 41% (Sears) | Winding ohms; ground test with a megohmmeter | Open or shorted winding, or locked | Replacement, $700 to $1,250 | Pro (EPA Section 608) |
Force the compressor on: the service-mode test
This test splits the problem in half without a meter. Sears Home Services explains that a bad thermistor (temperature sensor) keeps the compressor off in normal operation, while test mode forces it to run whether the thermistor works or not.
- Frigidaire top-freezer (sheet A01511101): press the fresh-food door switch 3 times and hold the fourth press until one long beep (all four presses within 2 seconds). Then press the switch twice: Test 1 powers the compressor. It stays on until the next test or for up to 5 minutes.
- Whirlpool (sheet W10480705): press and hold Door Alarm, press and hold Refrigerator Temperature up, release Door Alarm and wait 3 seconds until SE appears, then press up again and step to test 102 with the freezer temperature keys. Service Test 102 switches the compressor and condenser fan on and off with the refrigerator up and down keys.
Menus differ by model; Sears says the tech sheet is usually behind the bottom front grille or taped to the back.
If the compressor runs in service mode, the compressor and its start parts work. Sears points to the thermistor. To measure it yourself, unplug the refrigerator and use the meter's ohms setting. Whirlpool's tech sheet W10849496 lists 2,700 ohms (±5%) at 77°F, 7,964 ohms at 36°F and 23,345 ohms at 0°F for its sensors. A reading far off your sheet's chart, or none at all, points to the sensor. Afterward, see the right refrigerator temperature setting.
If it does not run in service mode, the fault is in the start relay, the wiring, the board or the compressor. Test them in that order.
Start relay and overload: test the $55 part first
Whirlpool's tech sheets list two compressor windings, run and start. The Sears PartsDirect listing for a common Whirlpool overload and start relay says it gives the motor its initial boost to start and protects the compressor from overcurrent by cutting the power if the temperature gets too high.
That is why Sears describes a failed start as repeated clicking. On Whirlpool's W10480705 sheet the compressor draws 13.0 amps with a locked rotor against 1.8 amps at full load, and the overload's short-time trip is 10 seconds (±5) at 14.3 amps. In practice, a compressor that cannot turn over keeps drawing several times its running current, the windings heat up, and the overload opens, cools, closes and tries again. Sears Home Services says a locked compressor may try to start, fail and click repeatedly.
The test (Sears Home Services' steps):
- Unplug the refrigerator, pull it out and remove the cover over the machine compartment at the bottom back.
- Unhook the retainer clip and pull the start relay straight off the compressor pins.
- Shake it. A rattle means the relay is burned out.
- No rattle: set the meter to continuity and test between the relay's terminals (terminals 5 and 6 on the relay in Sears' example). An open circuit means a bad relay.
- Refit the relay and its cover before you plug back in: Tecumseh's rule is never to energize a compressor unless the protective terminal cover is fastened.
Whirlpool's W10613606 is sold as a start device and capacitor (W10480705 lists a 12-microfarad run capacitor; testing one takes a capacitance meter). It cost $54.56 at Sears PartsDirect and $50.99 at iFixit on November 24, 2026. Match your model number before you buy.
Compressor windings: what the ohmmeter should read
If the relay is good, check the motor inside. Tecumseh's procedure for single-phase compressors:
- Wait for the internal thermal protector to reset, which can take as long as an hour on some compressors.
- With the power off and the relay removed, measure between the three pins: common to start (C–S), common to run (C–R) and start to run (S–R).
- No continuity on C–S or C–R means the compressor needs replacing.
- C–S plus C–R should equal S–R, within a small deviation, and each reading can also be compared with the compressor's specification.
Whirlpool's W10480705 gives 5.2 ohms (run) and 6.4 ohms (start), ±8% at 77°F, for its Embraco EM3Y60. Yours will differ; use your own sheet.
Two limits apply. Tecumseh says only a megohmmeter or Hi-Pot tester reliably finds that ground fault, and a reading below 2 megohms between any pin and the housing means one exists. That is a technician's tool. A compressor with good windings can still be mechanically locked; Sears lists a locked compressor first among the common reasons it does not run.
A failed compressor is sealed-system work. HomeGuide describes cutting the old one out, welding the new one in and recharging. Under the EPA's Section 608 rules, only a certified technician (or an apprentice closely supervised by one) may attach gauges to a refrigerator or add or remove its refrigerant.
Control board, wiring and variable-speed compressors
If the condenser fan is also dead, Sears Home Services suspects the electronic control board or the thermistor. Sears then checks continuity from the board through the wiring to the compressor (do this with the refrigerator unplugged). Sears treats around 5 ohms as continuity, which probably means the board is not sending voltage; an open reading means looking for pinched or broken wires. Sears also says a failing board may chatter or click and give off a burning odor.
Variable-speed (inverter) compressors are a different case. On Whirlpool's W10849496 sheet an inverter drives the compressor, and the sheet lists no start relay or overload for it. The inverter takes 120 volts AC and sending the compressor 0 to 15 volts DC at 40 to 150 hertz, and its windings read 12.03 ohms (±8%). Its Service Test 5 ramps the compressor from minimum to maximum speed. The sheet says only authorized technicians should take voltage measurements. On these models a silent compressor is a technician's question, and often a warranty question.
Model and brand differences
| Brand | Mode that stops cooling | Reset or forced test | Compressor warranty (one US document) |
|---|---|---|---|
| Whirlpool | "Showroom" (some models); some need turning back on after an outage | Service Test 102 on the W10480705 family | Years 2 to 5: parts and labor on the sealed system for French-door and side-by-side models |
| Frigidaire | Not covered in the sheets we read | Door switch sequence; Test 1 powers the compressor | Not checked |
| Samsung | Cooling Off: OF OF, O FF or OFF OFF | Power off 2 minutes; about 3 hours to see a drop | Sealed system 5 years parts and labor; digital inverter compressor 10 years parts, 5 years labor |
| LG | Demo: O F F | Exit sequence by model year | Sealed system and compressor 5 years parts and labor; linear or inverter compressor parts only in years 6 to 10 |
| GE | Diagnostic mode left on after service | Power off 30 seconds; clicking up to 5 minutes after an outage is normal | Not checked |
Warranty terms come from Samsung's US refrigerator warranty page, one LG US limited warranty and Whirlpool's limited warranty W11675876A. Terms vary by model; Whirlpool requires proof of purchase. Before you pay for a compressor, check the purchase date: on a five-year-old Samsung with an inverter compressor, the part may still be covered.
What it costs (checked November 2026)
| Item | Price | Source |
|---|---|---|
| Start device W10613606 (Whirlpool) | $54.56 | Sears PartsDirect, November 24, 2026 |
| Same part | $50.99 | iFixit, November 24, 2026 |
| Diagnostic visit | $60 to $100, often credited toward the repair | HomeAdvisor (updated June 19, 2026) |
| Minimum call-out fee | $70 to $130 | HomeGuide |
| Condenser fan motor, installed | $200 to $350 | HomeGuide |
| Thermostat, installed | $100 to $400 | HomeGuide |
| Control board, replaced | $400 to $750 (part $100 to $300) | HomeGuide |
| Compressor, installed | $700 to $1,250 (part $200 to $400) | HomeGuide |
HomeGuide's figures are dated April 5, 2023 (2026 headline). It calls a refrigerator worth repairing when it is less than 10 years old, has warranty coverage, and the repair costs less than half of a new unit; it puts a replacement at $675 to $2,500. HomeAdvisor gives the same 50% line. For the age and lifespan side of that decision, see the refrigerator troubleshooting guide.
Stop and call a pro if
- The breaker or GFCI trips again as soon as the refrigerator tries to start. Tecumseh calls a tripped breaker a strong indication of a ground fault.
- You hear sizzling, sputtering or popping from inside the compressor. Tecumseh's instruction is to get away immediately.
- You smell burning or hear the control board chattering.
- The relay tests good and the compressor still keeps clicking without starting, or a winding reads open.
- Your refrigerator has a variable-speed (inverter) compressor and service mode does not start it. The checks left need live voltage.
- The fix involves the compressor, the coils or the refrigerant. Under EPA Section 608, only a certified technician (or a closely supervised apprentice) may attach gauges or add or remove refrigerant.
Refrigerator compressor not running: common questions
Can you reset a refrigerator compressor?
Not with a button on most home refrigerators. Cutting power resets the control: GE says 30 seconds, Samsung 2 minutes. The overload resets itself once the compressor cools; on Whirlpool's W10480705 sheet it closes at 142°F, and Tecumseh says an internal protector can take up to an hour.
Why does my compressor click but not start?
Clicking for 3 to 5 minutes after a power outage is normal, per GE. Clicking that repeats while the cabinet warms usually means the compressor is trying and failing to start; Sears Home Services ties repeated clicking to a locked compressor. Test the start relay first, then have a technician check the compressor.
How long is food safe with the compressor off?
The FDA says food should be safe to eat if the fridge stayed at 40°F or below, or was above 40°F for 2 hours or less; if you are not sure how long it was above 40°F, throw the food out. Keep the doors closed while you test.
Is it worth replacing a refrigerator compressor?
Check the warranty first: Samsung covers the digital inverter compressor part for 10 years, LG covers linear and inverter compressor parts through year 10 in one US warranty, and Whirlpool covers the sealed system through year 5 on French-door and side-by-side models. Without coverage, set HomeGuide's $700 to $1,250 for the job against its $675 to $2,500 for a new refrigerator and apply the half-price test.
Sources
- Sears Home Services, Refrigerator compressor not running
- Penn State, EGEE 102: 6.4 Refrigerators
- Frigidaire, Service Data Sheet A01511101, Top Mount Freezer (FFHT1621Q)
- Frigidaire, Service Data Sheet 240389641, Side by Side
- Frigidaire, Why does my refrigerator run most of the time?
- U.S. FDA, Refrigerator Thermometers: Cold Facts about Food Safety
- Whirlpool Product Help, No Operation - Will Not Turn On - Refrigerator
- Whirlpool Product Help, Not Cooling - Refrigerator Section
- GE Appliances, Refrigerator - Normal Sounds and Noises Made
- GE Appliances, Refrigerator - Not Cooling Enough
- Samsung US, Cooling issues with your refrigerator or freezer
- LG US, How to disable Demo Mode
- Whirlpool, Tech Sheet W10480705 Rev A
- Whirlpool, Tech Sheet W10849496 Rev A
- Tecumseh, Service Handbook (North America)
- U.S. EPA, Section 608 Types of Technician Certification
- Samsung US, Refrigerator warranty
- LG, Refrigerator Limited Warranty for USA (owner's manual pages)
- Whirlpool, Major Appliance Limited Warranty W11675876A
- HomeGuide, How Much Does Refrigerator Repair Cost? (Sarah Noel, April 5, 2023)
- HomeAdvisor, How Much Does Refrigerator Repair Cost in 2026? (updated June 19, 2026)
- Sears PartsDirect, Whirlpool Refrigerator Compressor Overload and Start Relay W10613606
- iFixit, Whirlpool Compressor Start Device and Capacitor W10613606