Refrigerator Not Cooling? 11 Causes, Sorted by Which Section Is Warm

In short

  • Refrigerator not cooling? Read a thermometer first: the FDA's line is 40°F in the fridge and 0°F in the freezer, and the warm section tells you where to look.
  • Both sections warm: heat is not leaving the cabinet. Check the mode, the room, the coils and the condenser fan.
  • Freezer cold, fridge warm: cold air is not getting through. Look for frost on the evaporator, a stopped fan or a stuck damper.
  • Checked against: FDA, Whirlpool and GE Appliances support pages and service tech sheets.

Put one appliance thermometer in the fridge and another in the freezer, close the doors and read both after several hours (the wait is our suggestion). The FDA recommends keeping a thermometer in each section, because few refrigerator controls show the actual temperature inside. The target is 40°F or below in the fridge and 0°F in the freezer.

Those two numbers sort a cooling problem into one of two groups. If both read warm, the refrigerator is failing to push heat out into the kitchen. If the freezer is cold and the fridge is warm, the system is making cold but the air is not reaching the fresh-food side. The checks below follow that split, cheapest first, with the readings a technician would expect from Whirlpool and Frigidaire service sheets. For leaks, noises and other symptoms, start at the refrigerator troubleshooting guide.

freezer: coldfresh food: warm evaporator fanstopped: no air at the ventsevaporator coilpacked with frost: defrost faultdamperstuck closed: fridge gets no airheat out to the roomheld in by dust or a stopped fan ventskeep food 2 inches away condenser coilscondenser fancompressor vacuum the dustspin the blade, unpluggedsilent or clicking: technician
Freezer cold, fridge warm: the cold air is not getting through. Both sections warm: the heat is not getting out. Schematic, not to scale.

Quick checks first (free, about 15 minutes)

  1. Look for a display mode. A refrigerator in a store mode lights up but does not cool. On some Whirlpool models the display shows "Showroom". Samsung's Cooling Off mode shows OF OF, O FF or OFF OFF, and LG's demo mode shows O F F. Exits differ by brand and year; see the brand section below.
  2. Turn it back on after an outage. Whirlpool says some of its refrigerators need to be switched back on by hand after a power outage or surge.
  3. Check the control, then wait. Whirlpool sets the control mid-range at the factory and asks for at least 24 hours between one-step adjustments. The refrigerator temperature guide covers what each dial number means.
  4. Clear the vents. Whirlpool says air must flow freely between the freezer and fridge compartments, and a bulky item over a return vent breaks that loop. Samsung wants food 2 inches from the interior vents.
  5. Check the room. Whirlpool rates its refrigerators for rooms from 55°F to 110°F and for indoor household use only. A cold garage in January is outside that range.
  6. Close the doors properly. Close a door on a dollar bill or a sheet of paper and pull it out. A bill that slides out with no drag means the seal is not gripping there; Samsung's fix is to clean the seal with dish soap and a damp cloth and test again. Also press the light switch, or open the door about an inch: GE Appliances says the light should go out by then, and a light that stays on adds heat.

After any of these, read the thermometers again the next day. A newly installed refrigerator needs time: GE allows about 24 hours. After you change the setting, Samsung says the refrigerator can take up to 28 hours to reach the new temperature if the doors stay closed.

Refrigerator not cooling: 11 causes, cheapest test first

The order is our editorial judgment: free checks, then parts you can reach with the power off, then technician work. "How common" is our ranking from the makers' support pages, not a failure survey.

CauseHow commonThe testWhat you will seeFix or partDIY or pro
Demo, showroom or cooling-off modeCommon on new or reset unitsRead the displayLights on, no cooling; Showroom, OF OF or O F F on the displayExit the mode per the manualDIY
Control too warm, or changed less than a day agoCommonThermometer in each sectionFridge above 40°F, freezer above 0°FOne step colder, wait 24 hoursDIY
Blocked vents or a packed shelfCommonLook at the back wall ventsFood pressed against the vents; warm fridge, cold freezerMove food 2 inches from the ventsDIY
Room too hot or too cold, no clearanceCommon in garagesThermometer in the room; measure the gapsRoom outside the maker's range; unit pushed tight to the wallMove it or give it clearanceDIY
Door not sealing, light stays onCommonDollar-bill test; press the light switchBill slides out freely; light stays on with the door almost shutClean the gasket; replace it if it still failsDIY
Dusty condenser coilsCommon on older and compact modelsUnplug, remove the base grille, lookLint and pet hair on the coilsVacuum with a soft brushDIY
Condenser fan stopped or blockedOccasionalUnplug, open the rear bottom cover, spin the bladeBlade jammed by debris, or stiff on its shaftClear it; fan motor kit $75–$81DIY, unplugged
Defrost failure (heater, defrost thermostat, control)Common when the fridge is warm and the freezer coldRemove the freezer's back panel, unpluggedThick frost over the whole evaporator coilHeater about $91; defrost thermostat $31–$34DIY with care, or pro
Evaporator fan stoppedOccasionalListen and feel for air at the freezer ventsNo air movement while the compressor runsFan motor $54–$76DIY, unplugged, or pro
Damper stuck closedOccasionalFeel for air at the fridge ventsCold freezer, no frost, no air into the fridgeDamper or control (model-specific)Pro
Temperature sensor, control board, compressor or sealed systemLeast common, most expensiveTechnician's service test and gaugesWrong sensor reading; compressor clicking or silent; both sections warm with clean coils$100–$1,250 depending on partPro only

Both sections warm: the heat is not getting out

A refrigerator moves heat out rather than making cold. In Penn State's energy course, the compressor squeezes refrigerant gas until it is hotter than the room, the condenser coils on the back or bottom give that heat away, and the refrigerant then boils in the evaporator inside the cabinet, taking heat from the air and food. Lint, a jammed fan or a hot garage all stop the condenser shedding heat, and both sections warm together.

Dusty condenser coils

Whether you need to clean them depends on the model. GE Appliances says most of its refrigerators made since 2001 do not need coil cleaning, while compact and smaller top-freezer models may. Whirlpool says coils may need cleaning as often as every other month, depending on the room. The method: unplug the refrigerator, take off the base grille and vacuum the grille, the open areas behind it and the front of the condenser with a soft brush. Whirlpool also notes that some models can only be cleaned by a certified technician, so if the coils are sealed behind a panel you cannot open without tools, leave them.

Condenser fan stopped or blocked

Many refrigerators have a small condenser fan next to the compressor, behind the cover at the bottom of the back, that moves room air across the coils. It is a low-power part: the Frigidaire side-by-side service data sheet 240389641 lists its condenser fan motor at 3.1 watts and 1,100 RPM. Whether it runs only with the compressor depends on the design: Sub-Zero, for example, cycles it on and off with compressor run time on some models and runs it continuously on others. On a fan that cycles, a compressor humming at the bottom back while the blade beside it sits still makes the fan the suspect.

The safe test is mechanical. GE's unusual-noise steps describe it: pull the refrigerator out, unplug it, remove the cover at the bottom of the back (usually a 5/16-inch hex screw) and check the blade for anything caught in it, such as a wrapper. GE says the blade is visible there only on models without its NeverClean condenser, which it says most refrigerators made since 2001 have, so on many fridges there is no blade to check. GE links a sound like a playing card in bicycle spokes to this fault. With the power still off, turn the blade by hand. In practice, a blade that is stiff or grinds on its shaft points to a worn motor; one that spins freely and still does not run when plugged in needs a technician's live test.

The compressor is silent, or keeps clicking

GE lists clicking after a power outage as normal: it is the compressor trying to restart, and it can last 3 to 5 minutes. Clicking that keeps going well past that while both sections warm up, or a compressor that is silent while the lights work, belongs to a technician. The start relay, the compressor and the sealed system are covered on the refrigerator compressor not running page. Do not confuse long run times with a fault: Frigidaire says many of its French-door models use variable-speed compressors designed to run continuously, except during defrost.

Freezer cold, fridge warm: the cold air is not getting through

On many refrigerators the fresh-food side has no cooling coil of its own. GE Appliances explains that on its bottom-freezer models cold air is circulated from the freezer to the fresh-food compartment through a damper. That chain has three links you can check in order: the evaporator coil has to be free of ice, a fan has to push air across it, and the damper has to let that air through.

Frost on the evaporator: the defrost system

Every time a door opens, humid kitchen air comes in and its moisture freezes onto the evaporator coil behind the freezer's back panel. A frost-free refrigerator melts it off on a schedule with a heater. The Frigidaire sheet describes one family's routine: a 24-minute defrost every 6 to 96 hours of compressor run time, chosen by an adaptive control. When the heater, the defrost thermostat or the control fails, frost keeps building until air can no longer pass through the coil. HomeGuide's cost guide names the signs of a failed defrost heater as frost buildup on the evaporator and rising fridge temperatures.

The test. Unplug the refrigerator, empty the freezer and remove the panel on its back wall. In practice, a light, even coat of frost is normal; a coil packed solid with white frost means the defrost system has stopped clearing it. With the power still off, the defrost parts can be checked with a multimeter on the ohms setting:

  • Defrost heater: Whirlpool's tech sheet for one French-door family gives 30.4 ohms, and the Frigidaire sheet gives 30 ohms for its 450-watt heater. A heater that reads open (no continuity) cannot defrost.
  • Defrost thermostat: it is a temperature switch, and this is where many owners go wrong. The Frigidaire sheet gives a cut-in of 25°F and a cut-out of 47°F, so the switch only closes when it is cold. Read at room temperature it should be open; that is not a fault. In practice, test it straight after you open the panel, while it is still frosty and should show continuity, and check your own model's tech sheet for its values.

30.4 ohms ±5% is the defrost heater resistance on Whirlpool tech sheet W10849496, for a 435-watt, 115-volt heater.

Source: Whirlpool, Tech Sheet W10849496

Some controls can start a defrost for you, which tests the heater without a meter. On the Frigidaire family above, holding the Fresh Food up and down keys together for 5 seconds starts one, and the display shows "d" and "F" while it runs. In practice, melting the ice by hand (unplugged, doors open, towels down) brings the cooling back for a while; if the frost returns within days, a defrost part has failed. Ice on the freezer floor or water under the refrigerator points to the defrost drain instead, which is covered in refrigerator leaking water.

Evaporator fan stopped

HomeGuide puts it plainly: evaporator fan failure stops the fridge from cooling while the freezer still works. HomeGuide describes it as the fan that circulates cold air in the fridge; it sits next to the evaporator coil. With the doors closed and the compressor running, put your ear to the freezer's back wall and then your hand at its vent openings: you should hear the fan and feel moving air. GE notes the fan speed can change after door openings, so give it a few minutes with the doors shut.

If there is no air and the coil is not iced, unplug the refrigerator and turn the fan blade by hand. In practice, a blade that will not turn freely, or a motor that needs a push to start, is due for replacement. Do not test this fan with household voltage: on the Whirlpool tech sheet the evaporator fan motor is rated at 12.7 volts DC, and the sheet says only authorized technicians should take diagnostic voltage measurements. A fan that is frozen in place is a defrost problem, not a fan problem. A sound like the blade hitting something is, by GE's list, not normal and needs service.

Damper stuck closed

The damper is a small door between the freezer and the fridge; on the Whirlpool family above it is electric. GE lists a chirp, bark or "woof" as the normal sound of it opening or closing. If the coil is clear, the freezer fan is blowing and still almost no air comes out of the fridge vents, the damper or its control is the next suspect. The Whirlpool tech sheet gives its electric damper a maximum closing time of 16 seconds. Reaching a damper usually means removing interior ducts, so this is a technician job on most models.

Sensors and the control board

On electronic refrigerators the control board reads the cabinet temperatures through thermistors, sensors whose resistance rises as they get colder. HomeGuide lists temperatures that are too hot, too cold or wildly fluctuating as the sign of a broken thermostat, the control that sets how long the compressor runs. The Whirlpool tech sheet gives the resistance curve for its sensors; follow the tech sheet for your own model:

Sensor temperatureResistance (Whirlpool W10849496)
77°F2,700 ohms ±5%
36°F7,964 ohms ±1%
0°F23,345 ohms ±2%

Other brands use different sensors, so treat these numbers as one family's chart, not a universal test; the right chart is the tech sheet for your model number. On the same Whirlpool family the board can check its own fresh-food and freezer sensors in service mode and show 01 for pass, 02 for open or 03 for short. That mode is entered with the board's service switches and is meant for technicians.

Model and brand differences

From each maker's own support pages:

BrandRoom it is rated forClearanceStore mode looks likeTime to cool
Whirlpool55°F to 110°F, indoors onlySee the manual"Showroom" lit on some models; lights on, no coolingAbout 24 hours for the freezer after install
GE AppliancesMay not cool below 60°F or above 110°FAt least 1 inch each side, top and backNot covered on the page we checkedAbout 24 hours
SamsungWon't cool properly above 110°F or below 50°F2 inches back, top and sidesOF OF, O FF, OFF OFF or scrolling barsUp to 28 hours
LGSee the manualSee the manualO F F on the displaySee the manual

To leave LG's demo mode, the LG help library gives two sequences. On models built in 2018 and earlier, open the right door and hold Refrigerator and Ice Plus together for five seconds. On 2019 and newer models (serial number starting with 901 or higher), hold both buttons, then keep holding Refrigerator and press Ice Plus three times. Samsung's Cooling Off and Whirlpool's Showroom exits vary by model, so use the owner's manual. For power-cycle times by brand, see how to reset a refrigerator.

What it costs (checked November 2026)

We checked part prices on November 23, 2026, for common Whirlpool-built part numbers at two retailers; confirm your model number before ordering. Professional prices are HomeGuide's average repair costs.

RepairPart (Sears PartsDirect)Part (iFixit)Pro repair (HomeGuide)
Coil cleaningNoneNone$70–$130
Condenser fan motor kit W10124096$81.21$74.99$200–$350
Evaporator fan motor WPW10188389$76.26$53.99$250–$400
Defrost heater WPW10140847$90.60Not listed$120–$400
Defrost thermostat WPW10225581$34.38$30.99Not listed separately
Thermostat or controlModel-specificModel-specific$100–$400 (thermostat); $400–$750 (control board)
CompressorTechnician onlyTechnician only$700–$1,250
Refrigerant leak repairTechnician onlyTechnician only$400–$1,100

A visit costs money before any part: HomeGuide gives minimum service fees of $70 to $130, including up to an hour of labor and diagnostics, and HomeAdvisor (updated June 19, 2026) puts the diagnostic fee at $60 to $100, which many technicians credit toward the repair. HomeAdvisor's compressor range is far lower, $200 to $450, so get a written quote. Its rule of thumb is to consider replacing the refrigerator when the repair approaches 50% of the cost of a new one.

Stop and call a pro if

  • The compressor clicks on and off for much longer than the 3 to 5 minutes GE describes after an outage, or stays silent while the lights work and both sections warm.
  • Cooling is poor and you see oily residue or smell something musty, which HomeGuide lists as signs of a refrigerant leak. Under the EPA's Section 608 rules, anyone who attaches gauges to the system or puts in or takes out refrigerant must be certified (apprentices under close supervision excepted).
  • The coils are clean, the condenser fan spins, the freezer coil is clear, and both sections still sit above 40°F and 0°F a day later.
  • A fan, sensor or damper check would need live voltage readings; Whirlpool's tech sheet reserves those for authorized technicians.
  • You smell burning, see scorched wiring at the plug, or the breaker trips again right after you reset it.

Refrigerator not cooling: common questions

Why is my refrigerator not cold but the freezer is?

Because the fridge usually gets its cold air from the freezer. Clear the vents first, then look for heavy frost on the freezer's back wall (a defrost fault), then check that the evaporator fan blows and that air comes out of the fridge vents (fan or damper).

Why are both my refrigerator and freezer not cooling?

Heat is not leaving the cabinet. Check for a store mode, the room temperature, dusty coils and the condenser fan. If all four are fine, the compressor or sealed system needs a technician.

Is the food still safe?

The FDA says food is fine if the fridge stayed at or below 40°F, or was above 40°F for 2 hours or less.

Sources

  1. U.S. Food and Drug Administration, Refrigerator Thermometers: Cold Facts about Food Safety
  2. Whirlpool Product Help, Not Cooling
  3. Whirlpool Product Help, Not Cooling – Refrigerator Section
  4. Whirlpool, Tech Sheet W10849496 Rev A, French-door refrigerator (PDF)
  5. Frigidaire/Electrolux, Service Data Sheet 240389641, Side by Side, Automatic Defrost (PDF)
  6. Frigidaire, Why does my refrigerator run most of the time?
  7. GE Appliances, Refrigerator – Not Cooling Enough
  8. GE Appliances, Refrigerator – Adjusting Temperature Controls
  9. GE Appliances, Refrigerator – Normal Sounds and Noises Made
  10. GE Appliances, Refrigerator – Unusual Noises
  11. Samsung US Support, Cooling issues with Samsung refrigerator or freezer
  12. LG US Help Library, How to disable Demo Mode
  13. Sub-Zero, Condenser Fan Motor Operation
  14. Penn State, EGEE 102: 6.4 Refrigerators
  15. U.S. EPA, Section 608: Types of Technician Certification
  16. HomeGuide, How Much Does Refrigerator Repair Cost?
  17. HomeAdvisor, How Much Does Refrigerator Repair Cost? (updated June 19, 2026)
  18. Sears PartsDirect, Whirlpool Refrigerator Condenser Fan Motor Kit W10124096
  19. iFixit, Whirlpool Condenser Fan Motor Kit W10124096
  20. Sears PartsDirect, Refrigerator Evaporator Fan Motor WPW10188389
  21. iFixit, Whirlpool Refrigerator Evaporator Fan Motor WPW10188389
  22. Sears PartsDirect, Refrigerator Defrost Heater WPW10140847
  23. Sears PartsDirect, Whirlpool Refrigerator Defrost Bi-Metal Thermostat WPW10225581
  24. iFixit, Whirlpool Refrigerator Defrost Thermostat WPW10225581