How to Replace a Toilet Fill Valve (Test It First, Then Set the C.L. Mark)

In short

Replace a toilet fill valve only after a 10 to 15 minute test shows the valve, not the flapper, is wasting water: water spilling into the overflow pipe or a constant hiss points at the valve. A new universal valve costs about $13 to $18, or about $24 as a kit with a flapper (checked November 2026) and goes in with hand tools. Set its C.L. mark 1 inch above the overflow pipe and the water about 1/2 inch below the pipe's top.

Checked against: Fluidmaster 400A and Korky 528MP installation sheets, EPA WaterSense, NYC DEP.

A hiss from the tank long after the flush, or a thin stream of water running over the top of the overflow pipe, often means the fill valve is not closing. That is the tall valve on the supply-line side of the tank that refills it after each flush. According to New York City's Department of Environmental Protection, water can flow through an open fill valve at three to five gallons per minute. A valve that never shuts off is not a small leak.

Many fill valve complaints turn out to be a leaking flapper or a misplaced refill tube, so run the free checks first. For how the parts work together, see How a Toilet Works; for every other toilet fault, our toilet troubleshooting guide.

Quick checks first (free, about 5 minutes)

Take the lid off the tank and set it on a towel. Then:

  1. Watch the overflow pipe after the tank fills. Water trickling into its top means the valve lets in more than the tank holds. Fluidmaster's running-toilet guide starts with this check.
  2. Find the water line. It should stop about 1/2 inch below the top of the overflow pipe, the figure in both the Fluidmaster 400A and Korky 528MP instructions. Higher than that is often a setting, not a broken valve.
  3. Check the refill tube. It should be clipped to the overflow pipe so its end points into the pipe, not pushed down inside it. The Fluidmaster 400A sheet warns that shoving it down the overflow pipe can cause significant water waste.
  4. Open the shutoff valve fully. If the tank fills slowly, the shutoff valve under the tank may be only part open. Turn it counterclockwise as far as it goes.

Is it the fill valve? The diagnostic table

Causes are ordered by how cheap and fast the test is. Fluidmaster calls the flapper "the most common problem" when the tank level drops; the other frequency notes are our general guidance.

CauseHow commonThe testWhat you will seeFix or partDIY or pro
Tank water level set too highCommon, often right after a new valve goes inLet the tank fill and look at the overflow pipeWater trickles into the top of the overflow pipe; level at or above the pipe's topLower the float to 1/2 in below the pipe's top (free)DIY
Flapper leaking, so the valve refills on its ownThe most common cause of a dropping tank level, per FluidmasterShut off the water, mark the level in pencil, wait 10-15 minutes; or put a few drops of food coloring in the tank and wait 10 minutesThe level drops below the mark, or color shows up in the bowlNew flapper; see our flapper guideDIY
Refill tube pushed into the overflow pipeOccasionalLook at where the refill tube endsTube end is pushed down inside the overflow pipe, below the water line; the valve switches on by itself as often as every 15 to 30 minutesClip it to the pipe so it points in, not down inside; trim the tube (free)DIY
Debris on the valve sealCommon; Fluidmaster's first check when a valve will not shut offRemove the valve cap and flush the valve with a cup held over itGrit on the rubber seal; the hiss stops after cleaningClean it, or fit a new seal ($2.82 for a Fluidmaster 242)DIY
Worn seal or worn valvePossible once a valve is 7 years or olderClean the cap; watch whether the float cup drops when you flushHiss or overfill comes back; float cup stays up; rust or discoloration on the valveNew fill valve ($13-$18)DIY
Partly blocked shutoff valve or supply lineOccasionalWith the cap off, turn the water on briefly and watch the flowWeak flow out of the open valve, or a thumping noise during refillNew supply line; a stuck or leaking shutoff valve is a plumber jobDIY / pro

The pencil test also works during the refill. NYC DEP describes this version: mark the water line, flush and watch the tank refill. If the water first stops short of your mark and then keeps rising above it, the fill valve is the likely culprit. If the water rises above the mark and then goes back down, suspect the flapper. The dye test comes from EPA WaterSense; flush right after it so the color does not stain the tank. A tank that refills in short bursts with nobody using it is usually a flapper symptom, covered in Toilet Keeps Running. Rule out the refill tube first: Kohler explains that a refill hose whose end sits below the water line can siphon tank water into the bowl. On Kohler tanks with a canister flush valve, the hose belongs in the port on top of the flush valve, not on the overflow tube.

3 to 5 gallons per minute is how fast water can flow through a fill valve stuck open, according to New York City's water utility.

Source: NYC DEP, Detecting Toilet Leaks

Cause 1: the water level is set too high

A float-cup valve such as the Fluidmaster 400A shuts off when the plastic cup around its shaft rises with the water. If that shutoff point sits above the overflow pipe, the tank never reaches it: the extra water pours down the pipe into the bowl and the valve keeps running.

The fix (Fluidmaster 400A): flush, then turn the adjustment screw while the tank refills until the water stops about 1/2 inch below the pipe's top. Counterclockwise lowers the level; eight turns move the float about 1/2 inch, per the installation sheet. On a Korky 528MP the level is set by the height of the valve body instead, and Korky's sheet says plainly that a valve which won't shut off may simply be set too high.

Older ballcocks with a float ball on an arm do the same job. Fluidmaster's catalog describes its fill valves as the replacement for the ballcock, and NYC DEP is specific about the swap: do not replace an old fill valve that has a float ball with another float-ball valve; fit a piston-valve type, such as a float-cup valve, instead.

Cause 2: debris or a worn seal in the valve head

Inside the cap of a Fluidmaster-style valve, a rubber seal presses against a small seat to stop the water. A little grit on that seal can be enough to hold it slightly open, and you hear the water forcing through as a steady hiss. Fluidmaster's noise guide describes that hiss as water constantly passing through the fill valve into the tank.

The test and fix, step by step (400A-style valves):

  1. Turn off the water at the shutoff valve (clockwise) and flush to empty the tank.
  2. Push the float cup up and hold the shaft under it. With your other hand, turn the cap and lever counterclockwise 1/8 of a turn and lift the cap off.
  3. Look at the rubber seal inside the cap. Rinse off any grit.
  4. Hold a cup upside down over the open valve and turn the water on full force for 10 to 15 seconds, as Fluidmaster's slow-fill guide describes. This blows debris out of the valve inlet.
  5. Turn the water off, refit the cap and turn it clockwise to lock it.

Weak flow from the open valve, the 400A sheet says, points to a partial blockage at the shutoff valve or in the supply line (cause 3).

If the valve has been in use for years, or the float cup does not drop when you flush, the sheet says to fit a new 242 seal, which costs a few dollars. Replace the whole valve instead when you see rust or discoloration on it; Fluidmaster's maintenance page gives that as its replacement sign.

7 years is the age at which Fluidmaster says the working parts of a fill valve can start to wear out.

Source: Fluidmaster, Toilet Won't Fill or Slow Filling Tank

Skip drop-in bowl cleaners: Fluidmaster warns that in-tank cleaners with bleach or chlorine damage tank components and may cause flooding.

Cause 3: slow fill from the shutoff valve, supply line or pressure

A tank that fills slowly with a new or freshly cleaned valve is often starved upstream. Fluidmaster lists debris in the supply line or shutoff valve as a cause of slow filling, and its noise guide links a constant thumping during refill to an obstruction in the shutoff valve's flow path.

  • Supply line: Fluidmaster says to replace it if it is worn or more than 5 years old, and whenever you replace the whole fill valve.
  • Shutoff valve: debris can collect inside it, as Fluidmaster notes. If it will not open fully, or it drips at the stem when you turn it, leave it for a plumber (see the stop box below).
  • Pressure: Korky rates its 528MP for a minimum working pressure of 6 psi. At the other end, the PNNL Building America Solution Center notes that most plumbing codes require a pressure-reducing valve where supply pressure exceeds 80 psi. If the flow is weak at a sink too, read Low Water Pressure in One Faucet first.

How to replace a toilet fill valve, step by step

Tools: a bucket, a sponge, scissors and large adjustable pliers. The steps follow the Fluidmaster 400A installation instructions, with the Korky 528MP sheet noted where it differs.

  1. Mark the water line in pencil inside the tank as a reference.
  2. Shut off and drain. Turn the shutoff valve clockwise until it stops. Flush, hold the handle down, then sponge out the water left in the tank.
  3. Remove the old valve. With the bucket underneath, unscrew the supply line's coupling nut, then the large locknut under the tank, and lift the valve out.
  4. Size the new valve before you install it. Hold it in the tank beside the overflow pipe. For a 400A, the top of the valve must sit 3 inches above the overflow pipe, which puts the C.L. mark 1 inch above the pipe's top. Lift it out and twist the lower shank: counterclockwise makes it taller, clockwise shorter. Do not move the lock ring that holds the body to the shank. A Korky 528MP unlocks and slides instead; push it down until the water-level line on the valve sits about 1/2 inch below the overflow, then lock it.
  5. Install it. Put the shank washer on the threaded shank, flat side up, and set the valve in the hole. Turn the refill nipple to face the center of the tank. Press down on the valve from inside while you tighten the locknut underneath by hand only. Fluidmaster warns that overtightening may crack the valve or the tank and cause flooding. Check that the lid will close without touching the valve and that the float cup clears the tank walls, the flush lever and the flush valve.
  6. Attach the refill tube. Clip one end to the overflow pipe and push the other onto the valve's nipple, with a slight arch. Cut off any extra length so it does not kink, and never push it down into the overflow pipe.
  7. Reconnect the water. Inspect the supply line and replace it if it is worn or over 5 years old. Thread the coupling nut on by hand until tight. Korky says not to use sealant or tape on this connection.
  8. Turn the water on and check for leaks. If the connection under the tank drips, turn the nut just enough to stop it.
  9. Set the water level. Flush and adjust while the tank refills until the water stops about 1/2 inch below the top of the overflow pipe. Flush once more to confirm.
  10. Test. Wait a few minutes, then check that no water is running into the overflow pipe.
1 in or more 1 in Lever hole C.L. mark 1 in above the overflow top Float cup Fill valve Locknut hand-tight only Refill tube clipped to the pipe, end pointing in Water level 1/2 in below the overflow top Overflow pipe
Three settings to check after the swap: the C.L. mark 1 inch above the overflow pipe, the water 1/2 inch below its top, and the pipe's top at least 1 inch below the lever hole. Figures from the Fluidmaster 400A and Korky 528MP installation sheets. Schematic, not to scale.

Why the C.L. mark matters: the Fluidmaster sheet calls the 1-inch height a plumbing-code requirement and says code compliance helps protect your home and drinking water supply. The reasoning behind the rule: with the valve's critical level above the highest point the tank water can reach, tank water is kept from being drawn back into the supply line. Korky gives the same 1-inch rule for its valve, and both makers say the top of the overflow pipe must sit at least 1 inch below the lever hole.

Which replacement valve fits your toilet

Fluidmaster matches its valves to the toilet's age and flush volume, and lists toilets the 400A does not fit. Take these readings before you buy.

What to checkThe reading you wantIf it reads otherwise
Overflow pipe height, tank floor to the top of the pipe6 inches or taller for a Fluidmaster 400AShorter pipe: the 400A will not fit; look for the toilet maker's own valve
Gallons per flush marked on the toilet, and its age3.5 to 7 gallons and made before 1994: 400A or 400LS1.6 gallons or less from 1994 on, or dual flush or HET: see the valve table below
Where the supply enters the valveThrough the tank bottom, straight up into the valveA side-entry valve: Fluidmaster says the 400A does not replace it
Toilet typeTwo-piece toilet with a flapperOne-piece toilets and Glacier Bay or Niagara flapperless toilets are on Fluidmaster's not-supported list for the 400A

Fit rules: Fluidmaster's 400A page, its 400H PerforMAX page and Korky's 528MP product page.

ValveHeight rangeBest match, per the makerHow you set it
Fluidmaster 400A9 to 14 inToilets made before 1994 with 3.5 to 7 gallons per flush; 5-year warrantyScrew on top of the float cup (8 turns = 1/2 in)
Fluidmaster 400LS Leak Sentry9 to 14 inSame pre-1994, 3.5 to 7 gallon toilets; stops the automatic refill of a tank with a worn or faulty flapper; 5-year warrantyIts chain clips to the tank lever with no slack; a roller clamp sets the bowl refill
Fluidmaster 400H PerforMAX9 to 14 inToilets made after 2005, or sold as dual flush, high performance or HET (high-efficiency toilet); Fluidmaster claims 2X greater bowl refill; 7-year warrantyAn independent knob changes the bowl refill without changing the tank level
Fluidmaster 400AH PerforMAX10 to 15 inSized for toilets of 1.6 gallons per flush or lessA roller clamp regulates the bowl refill (per the 400ARHFCS kit that replaces the 400AH)
Korky 528MP QuietFILL Platinum8-1/2 to 14 inToilets made since 1994 at 1.6 gallons per flush or less; minimum 6 psiValve height plus a refill adjuster for the bowl

The refill tube tops up the bowl while the tank refills, and Fluidmaster says the 400H's bowl adjustment helps 1.28 gpf and lower-flow toilets flush efficiently. On a 400LS, the chain is how the leak lockout works: Fluidmaster's adjustment page says to hold the tank lever up, pull the chain until it lifts the float cup all the way up the shaft and clip it with no slack. If the tank then will not refill, take up the slack in the chain.

Our pick, by toilet: for a two-piece toilet from before 1994, the 400A is the maker's match; choose the 400LS at $14.02 instead if the flapper has leaked before, since it will not keep refilling a leaking tank (Fluidmaster's 400LS page). For a 1.6 gpf toilet from 1994 to 2005, the Korky 528MP or a PerforMAX 400AH kit fits the maker's ratings. For a 1.28 gpf, dual-flush or other HET toilet, choose the 400H for its separate bowl knob. For a one-piece, flapperless or side-entry toilet, check the toilet maker's part first; Fluidmaster sells a separate 703A valve for Glacier Bay and Niagara toilets.

Other specs: Fluidmaster's retail catalog and the Korky sheet. Kohler sells its own replacement fill valves, GP1138930 and GP1083167, shown in a Kohler support video; check Kohler's parts list for your model first if the tank carries a Kohler-branded valve.

What it costs (checked November 2026)

ItemPriceWhere we checked
Fluidmaster 242 replacement seal$2.82The Part Works
Korky replacement cap assembly$3.62PlumbingSupply.com
Korky 528 QuietFILL valve$13.15PlumbingSupply.com
Fluidmaster 400LS Leak Sentry valve$14.02PlumbingSupply.com
Fluidmaster 400A valve$18.27PlumbingSupply.com
Fluidmaster PerforMAX 400ARHFCS kit (valve, adjustable flapper, connector)$24.14PlumbingSupply.com
Plumber replaces the fill valve, labor included$60 to $150Fixr cost guide, updated January 31, 2025

Single-unit online prices from PlumbingSupply.com's Fluidmaster page, its Korky page and The Part Works, before shipping. The Fixr toilet repair cost guide also puts plumbers at $45 to $200 per hour and a shutoff valve replacement at $60 to $150.

Stop and call a pro if

  • The shutoff valve under the tank will not turn, will not close fully, or drips at the stem when you move it. Shut off the main water valve and call a plumber; forcing an old valve risks breaking it.
  • You see a crack in the tank, or water keeps appearing on the floor after you have reseated the valve and tightened the nut only by hand.
  • Water is leaking where the supply pipe comes out of the wall or floor, not at the valve connection.
  • You suspect high house pressure: most plumbing codes require a pressure-reducing valve above 80 psi, and fitting one is a plumber's job.
  • The water is coming from under the toilet, not the tank; read Toilet Leaking at the Base first.

FAQ

Why does my toilet refill by itself every 15 to 30 minutes?

Either the flapper is leaking or the refill hose sits below the water line and siphons. Check the hose first, since it costs nothing: Kohler says a hose below the water line can leak about one drop every 3 seconds and make the valve switch on as often as every 15 to 30 minutes. If the hose is clipped correctly, run the dye test; color in the bowl means the tank is leaking into the bowl, at the flapper or the flush valve seat.

Is it normal for a new fill valve to drip while it fills?

For the Korky 528MP, yes. Korky says water can come from the base of the shaft and the cover seam while it is refilling.

Sources

  1. Fluidmaster, 400A Universal Fill Valve product page
  2. Fluidmaster, 400H PerforMAX Toilet Fill Valve product page
  3. Fluidmaster, 400LS Leak Sentry Universal Fill Valve product page
  4. Fluidmaster, Adjusting Leak Sentry or Leak Guard Toilet Fill Valve
  5. Fluidmaster, 400A Fill Valve Installation Instructions (Part 4-743, Rev. 6, 08/14)
  6. Fluidmaster, Toilet Won't Fill or Slow Filling Tank
  7. Fluidmaster, Toilet Running Constantly
  8. Fluidmaster, Determining Your Toilet's Noise and How to Fix It
  9. Fluidmaster, How to Maintain a Fluidmaster Fill Valve
  10. Fluidmaster, Retail Catalog (Expanded), FM91438
  11. Korky, QuietFILL Platinum 528MP Installation Instructions (6.2026)
  12. Korky, QuietFILL Platinum Toilet Fill Valve 528MP product page
  13. Kohler, GP1138930 and GP1083167 Universal Fill Valve Replacement (video)
  14. Kohler, Tank Leak: Fill Valve Hose Position
  15. U.S. EPA WaterSense, Fix a Leak Week
  16. NYC Department of Environmental Protection, Detecting Toilet Leaks
  17. PNNL Building America Solution Center, Service Water Pressure
  18. PlumbingSupply.com, Fluidmaster Toilet Fill Valves (prices checked November 2026)
  19. PlumbingSupply.com, Korky Fill Valves (prices checked November 2026)
  20. The Part Works, Fluidmaster 242 Replacement Seal (price checked November 2026)
  21. Fixr, Toilet Repair Cost (updated January 31, 2025)