Toilet Keeps Running? Time the Refills to Find the Leak (Parts From $3.35)
In short
A toilet that keeps running is losing tank water one of two ways: over the top of the overflow pipe (a fill valve that will not shut off, or a water level set too high) or past the flapper into the bowl. Fluidmaster calls the flapper the most common problem. Its test: tank full, water off, mark the level and wait 10 to 15 minutes. The usual part costs $3.35 to about $24 (checked November 2026). Checked against Fluidmaster, Kohler, NYC DEP and EPA WaterSense.
Jiggling the handle is the fix everyone knows, and it is also a test. If the running stops when you jiggle it, something was holding the flapper off its seat, most likely the chain or a sticking handle, and you have found the fault. If it keeps running, the water is leaving another way, and every jiggle after that only hides the clue. Do not leave it for the weekend: New York City's Department of Environmental Protection says water can flow through an open fill valve at three to five gallons per minute. Below, the causes are tested cheapest first. For other toilet faults, start at the toilet troubleshooting guide.
Five-minute checks first
- Find the shutoff. The small valve on the supply line behind the toilet closes clockwise. If water is on the floor, Fluidmaster says to turn it off right away.
- Lift the tank lid and look at the overflow pipe. Water spilling over its top edge points to the fill side, the first question in Fluidmaster's running-toilet guide. Water sitting below the top while the toilet runs is most likely leaving past the flapper.
- Jiggle the handle once. If that stops it, skip to the handle and chain section below.
- Run the dye test. EPA WaterSense says to put a few drops of food coloring in the tank and check the bowl after 10 minutes. Color in the bowl means a leak. Fluidmaster adds that dye can miss a slow one.
- Time the refills. If it refills when nobody has used it, note the time between refills.
How often it refills tells you where the water goes
A fill valve opens when the tank level drops, so a refill nobody asked for means the tank lost water. Fluidmaster's 400A instructions say exactly that. The intervals overlap, so treat the right-hand column as a first suspect and confirm it with the pencil test below.
| What you notice | Where the water is going | First suspect |
|---|---|---|
| Runs nonstop; water spills over the top of the overflow pipe | Down the overflow pipe into the bowl | Water level set too high, or a fill valve that will not close |
| Runs nonstop; stops when you jiggle the handle | Past a flapper that is held open | Chain too tight or snagged, or the handle binding |
| A constant hiss | Through the fill valve into the tank | Debris in the fill valve |
| Refills every few seconds or every few minutes | Past the flapper into the bowl | Worn or dirty flapper, or a damaged seat |
| Refills as often as every 15 to 30 minutes from a very slow drip | Siphoning through the refill hose | Refill hose end sitting below the waterline (Kohler) |
| Refills hours or days apart | Under the flush valve, into the bowl | Flush valve gasket (Fluidmaster) |
| Tank loses water but no dye reaches the bowl | Out of the toilet, at the back or underneath | Fill valve locknut, supply line or tank-to-bowl seals |
| Fill valve turns on at odd times, or after a change in water pressure | Down the overflow pipe while the valve is forced open | A pressure spike in the line (Kohler, NYC DEP) |
The seconds-versus-days split is from Fluidmaster's leak guide; the 15 to 30 minutes is Kohler's.
3 to 5 gallons per minute can flow through an open fill valve, up to 4,000 gallons in a day.
Source: NYC Department of Environmental Protection, Toilet Leak Detection
Causes in order of likelihood, with the test for each
Fluidmaster names the flapper the most common problem, and NYC DEP names the flapper and the fill valve the two most common causes. The rest of the order is our editorial judgement from the guides in Sources, weighted by how cheap each test is, not a measured frequency.
| Cause | How common | The test | What you will see | Fix or part | DIY or pro |
|---|---|---|---|---|---|
| Flapper worn, warped or dirty | Most common | Water off, pencil mark at the waterline, wait 15 minutes | Level drops and stops just below the flapper | Wipe it and the seat; replace if over 5 years old ($3.35 to $17.85) | DIY |
| Water level set too high | Common, free to fix | Measure water to overflow top after a refill | Water at the top edge, trickling in | Lower the float to 1/2 in. below the top | DIY |
| Fill valve not closing (debris, worn seal, sinking float) | Common | Lower the level; still overflowing, flush debris from the valve | Water keeps reaching the overflow, or a hiss continues | Clean it; new seal, or a new valve ($13.15 to $24.14) | DIY |
| Chain too tight, tangled or caught; handle binding | Common, free to check | Watch the flapper drop after a flush | Flapper hangs open until you move the handle | Set the slack; new lever if it binds | DIY |
| Refill tube siphoning | Uncommon (Kohler) | Look at where the tube ends | Tube end inside the overflow pipe, below the waterline | Clip it so the end sits above the water | DIY |
| Nicked or rough flush valve seat | Occasional | Tank empty, run a finger around the seat rim | Nicks, grit cuts or corrosion; a new flapper still leaks | Seat repair kit ($9.18) or a new flush valve | DIY |
| Cracked overflow pipe | Occasional, on older plastic | Pencil test; look just above where the level stops | Level stops partway up the pipe, at a crack | New flush valve (tank comes off) | Skilled DIY or pro |
| Flush valve gasket | Less common, slowest leak | Pencil test, left as long as it takes | Tank drains almost completely; refills hours or days apart | Tank off, tighten the nut or replace the gasket | Pro for most owners |
| External leak | Occasional | Level drops, no dye in the bowl; check underneath with a flashlight | Drips at the fill valve nut, supply line or tank bolts | Snug the nut by hand; new washers or bolts | DIY or pro |
| High or spiking water pressure | Less common | Pressure gauge on a faucet, nothing else running | Above 80 psi with nothing running | Pressure-reducing valve | Pro |
Water over the top of the overflow pipe: level and fill valve
The fill valve shuts when its float rises to its set height. Whatever it fails to stop goes down the overflow pipe into the bowl. Set the level first, because a level that is too high looks exactly like a broken valve.
The test. Let the tank refill and go quiet, then measure from the water surface up to the top of the overflow pipe. Fluidmaster's 400A fill valve instructions put the water level below the top of the pipe and recommend 1/2 inch. On that valve, turning the adjustment screw counterclockwise lowers the level, and eight turns move the float about 1/2 inch. Flush and measure again.
If lowering it does not help, Kohler's troubleshooting sheet says to clean or replace the fill valve. Fluidmaster says debris can lodge inside the valve. Its cleaning steps: water off, flush, twist the cap off an eighth of a turn counterclockwise, hold a cup upside down over the open valve and run the water full force for 10 to 15 seconds. A long-serving valve may need a new seal (Fluidmaster's part 242). Kohler also says to replace the fill valve if the float sinks.
NYC DEP says not to replace an old float-ball valve with another float-ball valve; use a piston-type fill valve. Whatever you fit, the critical-level mark (C.L.) printed on the valve must sit 1 inch above the top of the overflow pipe; Fluidmaster calls this a plumbing code requirement. The full swap is in how to replace a toilet fill valve.
Level drops with the water off: flapper and seat
EPA WaterSense describes the flapper as a simple rubber device that holds water in the tank and releases it into the bowl when you flush. Fluidmaster says flappers usually last about 3 to 5 years, that hard-water deposits stiffen them, and that drop-in bleach tablets very often damage them. NYC DEP adds that the damage often happens while a house stands empty, as chlorine builds up in unflushed tank water.
The pencil test is Fluidmaster's procedure for finding the leak point:
- With the tank full, close the shutoff. Do not flush.
- Mark the waterline on the inside of the tank with a pencil.
- Wait 15 minutes. If the level has dropped, mark it again and keep waiting until it stops moving.
Water falls to the height of the leak and stops there. If it stops just below the flapper, the flapper or its seat is leaking. If the tank drains almost empty, suspect the flush valve gasket. If it stops partway up the overflow pipe, look for a crack just above the water: Fluidmaster says cracks in brittle old plastic overflow pipes are not uncommon.
The fix. Fluidmaster's rule is simple: if the flapper is more than 5 years old, change it. If it is younger, wipe the flapper and seat with a clean cloth, then run a finger around the seat rim for nicks; NYC DEP notes that grit and sediment can cause small cuts in the flush valve. A seat repair kit such as Fluidmaster's 555C fits over the old seat with its own flapper. Flappers come in 2-inch and 3-inch sizes, and on a 1.6-gallon toilet, NYC DEP says to make sure the replacement is adjusted correctly for a water-saving toilet. Sizing and the swap itself are in how to replace a toilet flapper.
The handle or chain holds the flapper open
If jiggling the handle stops the running, the flapper is not dropping onto its seat by itself. A chain that is too short keeps the flapper slightly lifted. A chain that is too long can snag. Kohler wants one to two links of slack at most and says to remove extra chain so it cannot catch on the trip lever arm. Fluidmaster's 400A sheet uses about 1/2 inch of slack.
Check the handle too. Kohler's running-toilet page lists a binding trip lever arm as a cause, and its troubleshooting sheet says to adjust the trip arm bracket and flange so they sit parallel with the top of the tank. A lever that still sticks is a cheap part to replace.
The refill tube is siphoning the tank
The thin refill tube from the fill valve tops up the bowl through the overflow pipe after each flush. If its end sits below the tank waterline, water can siphon back out through it. Kohler describes the leak as slow, perhaps one drop every 3 seconds, enough to start the fill valve as often as every 15 to 30 minutes.
The fix is free. Clip the tube to the overflow pipe so its end stays above the tank water level; Fluidmaster warns not to shove it down the pipe. On Kohler tanks with a flapper, the clip is part 51261, and Kohler says a paperclip works only as a stopgap because it corrodes quickly. On Kohler canister models, the hose may have come off its port; reconnect it to the port at the top of the flush valve.
The tank empties slowly: flush valve gasket or a cracked overflow
When the refills come hours or days apart and the pencil test drains the tank nearly dry, the leak is under the flush valve. Fluidmaster says gasket leaks are usually invisible and almost always run into the bowl, and Fluidmaster also notes that dye does not always reveal a slow leak.
On a two-piece toilet, Kohler's fix is to take the tank off the bowl, tighten the flush valve nut and, if the leak continues, replace the gasket, without over-tightening. Fluidmaster's limit is no more than 1/2 turn beyond hand tight, and its fill valve sheet warns that over-tightened nuts can crack the tank or bowl. Fluidmaster also lists a cracked plastic overflow pipe as a cause, since the plastic can become brittle over time. Replacing the flush valve is Fluidmaster's step when a tank keeps draining after a new flapper, and that job means taking the tank off, which some owners hand to a plumber.
Tank loses water but the bowl stays clear
If the pencil test shows a drop and the dye never reaches the bowl, the water is leaving the toilet, not running through it. Fluidmaster's ghost-flushing guide says water at the back of a toilet most likely comes from the bottom of the fill valve, the supply line or, on a two-piece toilet, the seals between tank and bowl. Dry those spots and watch them with a flashlight. Fluidmaster says the fill valve locknut should sit tight against the tank and be hand-tightened. Water around the base of the toilet is a separate problem, covered in toilet leaking at the base.
Water pressure: when the toilet is fine and the house is not
Pressure is the cause to suspect last, after the pencil test has cleared the tank. Kohler lists a line pressure spike among the reasons a valve turns on, and NYC DEP says a change in a home's water pressure can leave the fill valve stuck open with water running down the overflow tube. Kohler states the code range for gravity toilet tanks as 20 psi minimum to 80 psi maximum, static.
The test. The Portland Water Bureau suggests an inexpensive pressure gauge from a hardware store. Thread it onto an outdoor or laundry faucet and read it with no water running anywhere in the house, which is what static pressure means in PNNL's Building America guide. Portland says plumbing code requires a pressure-reducing valve if a home receives more than 80 psi. Fitting or replacing one is a plumber's job. If pressure is low instead, see low water pressure in one faucet.
Model and brand differences
- Canister and tower valves (Kohler canister models and others). These use a flat seal instead of a flapper, per Fluidmaster. Kohler says flapper and canister seals both wear from water conditions and in-tank cleaners, and it recommends replacing the flush valve gasket as well so the leak is fully stopped.
- American Standard Champion. The Champion uses an accelerator flush valve with its own seal. American Standard says that if you hear water running continuously you may need to replace that seal; after shutting off and draining the tank, the job includes removing the clevis pin from the trip lever rod.
- Pressure-assist toilets (Sloan Flushmate in Kohler bowls). For one that runs continuously, Kohler says to open the supply stop fully, set the gap between actuator and plunger arm to about 1/8 inch and clean the screen. Plunger arm and lower supply group repairs go through Kohler customer care.
- Flushometer toilets with no tank. NYC DEP says moving water in the bowl after the flush means the valve is leaking and needs repair or replacement, and that phantom flushes from building pressure changes should be checked by a licensed plumber.
- Leak Sentry fill valves. Fluidmaster's 400LS stops the automatic refill when a flapper leaks. NYC DEP explains the trade-off: the tank drains and stays empty, so the next user flushes twice.
What it costs to fix (checked November 2026)
Prices checked in November 2026. EPA WaterSense suggests taking the old flapper, or a picture of it, to the store.
| Part | Price | Where |
|---|---|---|
| Korky 2001 universal 2-in. flapper | $3.35 | PlumbingSupply.com |
| Fluidmaster 5403 3-in. adjustable flapper | $17.85 | PlumbingSupply.com |
| Fluidmaster 555C 2-in. seat repair kit | $9.18 | PlumbingSupply.com |
| Korky 528 QuietFill fill valve | $13.15 | PlumbingSupply.com |
| Fluidmaster 400ARHFCS PerforMAX fill valve kit | $24.14 | PlumbingSupply.com |
| Fluidmaster 400LS Leak Sentry fill valve | $14.02 | PlumbingSupply.com |
| Kohler canister valve seal GP1059291 | $10.44 | PlumbingSupply.com |
For a plumber, HomeAdvisor (updated June 19, 2026) puts a running toilet at $100 to $400 and adds $100 to $300 for after-hours emergency work. Fixr (updated January 31, 2025) gives $50 to $400 for a running toilet and $50 to $100 for a chain repair.
Stop and call a pro if
- The shutoff valve behind the toilet will not close, or leaks at the stem when you turn it.
- The pencil test drains the tank almost empty and you are not ready to lift the tank off the bowl.
- You find a crack in the tank itself, not just the plastic overflow pipe.
- A pressure gauge reads above 80 psi with nothing running, or a new fill valve still turns on by itself.
- Water keeps dripping from the tank bolts or the supply connection after hand-tightening.
- A flushometer or pressure-assist toilet keeps running after you have opened the supply stop fully.
FAQ
Why does my toilet run by itself for a few seconds?
The tank is losing water and the fill valve is topping it up. Use the refill timing table above: seconds to minutes apart points to the flapper, hours or days apart to the flush valve gasket.
Why does it still run after I replaced the flapper?
Check the chain slack, the water level against the overflow pipe and the refill tube first. Then run a finger around the seat for nicks. If the tank still drains down, Fluidmaster's next step is a new flush valve.
Can I just close the shutoff until I fix it?
Yes. It stops the waste; open it to refill the tank before each flush.
How often should a flapper be replaced?
EPA WaterSense says to check it periodically and replace it at least every five years.
Do in-tank cleaning tablets cause a running toilet?
They can: NYC DEP says in-tank cleaners can corrode the rubber parts in the tank. For how all these parts work together in one flush, see how a toilet works; if the flush is weak rather than endless, see toilet won't flush properly.
Sources
- Fluidmaster, How to Fix a Toilet That is Constantly Running
- Fluidmaster, How to identify and fix toilet flapper leaks
- Fluidmaster, Fix Toilet Ghost Flushing and Refill Sounds
- Fluidmaster, Determining Your Toilet's Noise and How to Fix It
- Fluidmaster, 400A Fill Valve Installation Instructions (Part 4-743)
- Fluidmaster, How Often To Replace Toilet Flapper
- Kohler Assist, Toilet Occasionally Leaking or Running
- Kohler Assist, Tank Leak: Fill Valve Hose Position
- Kohler Co., Toilet Troubleshooting, document 1175975-5-B
- Kohler Assist, Minimum and Maximum PSI for Plumbing Fixtures and Faucets
- American Standard, How to Replace the Accelerator Flush Valve Seal in Your Champion Toilet
- NYC Department of Environmental Protection, Toilet Leak Detection
- U.S. EPA WaterSense, Fix a Leak Week
- Portland Water Bureau, Water pressure and flow
- PNNL Building America Solution Center, Service Water Pressure
- PlumbingSupply.com, Toilet flappers (prices checked November 2026)
- PlumbingSupply.com, Fluidmaster toilet fill valves (prices checked November 2026)
- PlumbingSupply.com, Korky fill valves (prices checked November 2026)
- HomeAdvisor, How Much Does Toilet Repair Cost in 2026? (updated June 19, 2026)
- Fixr, Toilet Repair Cost (updated January 31, 2025)