Water Heater Troubleshooting Guide: Gas, Electric and Tankless Problems by Symptom

Problems we cover

In short

  • Water heater troubleshooting starts with the fuel: on an electric tank with no hot water, A.O. Smith checks power, then the red reset button, then the elements; on a gas tank, start at the pilot.
  • A good electric element reads 5 to 25 ohms with the power off.
  • A relief valve that drips while nobody runs water often points to thermal expansion.
  • Checked against: A.O. Smith technical bulletins, Watts, CPSC.

No hot water at all, hot water that runs out halfway through a shower, a puddle under the tank, a rumble when the burner fires, or hot water that smells of rotten eggs. Each of those has a first test you can do in a few minutes with a flashlight, a bucket, a kitchen thermometer or a multimeter.

The table below matches each symptom to its likely cause and first test; the sections after it give the readings to expect, from A.O. Smith's technical bulletins and service flowchart, the Watts relief valve sheet, Rinnai's tankless FAQ and CPSC scald data. We checked prices in November 2026 (editorial policy). This page belongs to the plumbing and water guide, and every test stays inside our safety policy: no gas line work, no work inside the electrical panel.

Water heater symptoms, likely causes and the first test

What you noticeMost likely causeFirst testWhat the result meansGo to
Electric tank, no hot waterTripped breaker or high-limit (ECO), failed upper element or thermostatBreaker off, press the red reset buttonClick: the water overheated. No click: test the upper elementElectric, no heat
Gas tank, no hot waterPilot out or will not stay litLook for the pilot flame through the sight windowGoes out when you release the knob: thermocouplePilot
Hot water runs out fastLow setting, broken dip tube, failed lower element, tank too smallA.O. Smith depletion testMore than about 30°F lost at 60% of tank volume: dip tube or lower elementRuns out fast
Water on the floorCondensation, drain valve, relief valve, a fitting, or the tankDry everything; watch where the first drop formsWater from the tank body: replace the heaterWater heater leaking
Relief valve dripsThermal expansion or high supply pressureDoes it drip while heating with no tap open?Yes: most likely thermal expansion; an expansion tank is the usual fixRelief valve
Rumbling or poppingLime and sediment on the tank bottomListen while it heats; check the ageNoise that continues after a flush: call a proNoise
Hot water smells of rotten eggsSulfate-reducing bacteria and the anode rodSmell hot and cold taps separatelyHot only: the heater. Smell in the air: treat as a gas leakAnode rod
Tankless stays coldFlow below the minimum, clogged inlet screen, a fault codeOpen the hot tap fully; read the displayFires at higher flow: the flow was too lowTankless
Water far hotter than the settingThermostat contacts welded shutThermometer at the tapWell above the dial: call a proElectric, no heat

Free checks first: breaker, reset button, setting

GE Appliances' list includes cheap causes: a blown fuse or tripped breaker, a temperature set too low, a tripped manual-reset high limit (ECO), a faucet left open, or hot and cold connections reversed. GE also notes incoming water is colder in winter and takes longer to heat; that is normal.

  1. Breaker. An electric tank runs on 240 volts, and PNNL notes there are usually two breakers to switch. Reset a tripped one once. If it trips again, stop: that points to a fault in the wiring or the heater, which belongs to an electrician.
  2. Reset button (electric). Turn the breaker off and confirm the heater is dead with a non-contact voltage tester. Remove the upper access panel, fold back the insulation and press the red reset button without touching the terminals; refit both before restoring power. In A.O. Smith's flowchart, a click means the water got too hot and tripped the Energy Cut Off. Never bypass or jumper the ECO; a trip that repeats means a stuck thermostat or a shorted element.
  3. Setting. Measure, do not guess. The CPSC says to hold a candy or meat thermometer under the tap first thing in the morning, or two hours after hot water was last used, and urges a 120°F setting.

6 seconds in 140°F water is enough to cause third-degree burns; at 120°F, a five-minute exposure could.

Source: CPSC, Avoiding Tap Water Scalds

How a tank water heater works

Hot water leaves from the top of the tank, and cold water flows into the bottom to replace it, which starts the heating, as Montana State University Extension describes it. The cold water reaches the bottom through the dip tube. A damaged dip tube is one of the parts A.O. Smith says to check when hot water runs out early.

A gas tank has one burner under the tank, a pilot, and a flue up the center. An electric tank has an upper and a lower element, each with its own thermostat. Both have a temperature and pressure (T&P) relief valve near the top, a drain valve near the bottom, and an anode rod that corrodes so the steel tank does not. The full cycle is in how a tank water heater works.

cold inhot out T&P valveupper thermostatwith red reset buttonupper elementaccess paneldischarge pipelower thermostatlower element dip tubeanode roddrain valvesediment
An electric tank in cross-section. The upper and lower elements and their thermostats sit behind access panels on the side; the red reset button is on the upper thermostat. A gas tank has one burner under the tank and a flue up the center instead of the two elements. Schematic, not to scale.
PartIts jobHow it failsSymptom
Dip tubeTakes cold water to the bottomCracks or comes apartHot water runs out fast
Upper element and thermostatHeat the top of the tankElement fails; thermostat sticksNo hot water
Lower element and thermostatHeat the rest of the tankElement fails or scales overShort supply
Pilot and thermocouple (gas)Light the burner; prove the flameThermocouple weak or out of the flamePilot will not stay lit
High-limit (ECO)Shuts heating off if water overheatsTrips when a thermostat sticks onNo hot water; reset clicks
T&P relief valveOpens at its pressure rating or 210°FOpens for thermal expansion; deposits jam itDripping discharge pipe
Anode rodCorrodes in place of the tankUsed up; reacts with sulfatesRotten-egg smell
Drain valveLets you flush sedimentStops closing fullyDrip at the bottom front

Electric water heater not heating: the A.O. Smith test sequence

A.O. Smith's "Standard Electric - No Hot Water" flowchart is the clearest test order we found. Its first step, checking for 240 volts at the upper thermostat, is a live test; leave it to an electrician. Before every test below, switch the breaker off and confirm the heater is dead with a non-contact voltage tester.

  1. Reset did not click. Test the upper element: disconnect its two power wires, set the multimeter to its lowest resistance range and measure across the two screw terminals. A good element reads 5 to 25 ohms, about 12.5 on a typical one; outside that range, replace it. If the element is good, A.O. Smith says to replace the upper thermostat.
  2. Reset clicked. Something kept heating. Disconnect the wires from each element, set the meter to its highest range, and measure from each terminal to the metal tank or thermostat bracket. A good element reads OL; any lower reading means it is grounded and must be replaced. If both pass, the thermostat contacts have probably welded shut, leaving an element on. The lower thermostat does most of the work, so A.O. Smith names it as the likelier failure.
  3. Everything tests good. The flowchart's last step is a leak on the hot side of the plumbing, since hot water leaking away looks like a heater that cannot keep up.

PNNL notes that mineral deposits on an element reduce how well it passes heat to the water, so the flush in the noise section is element maintenance too.

Gas water heater: pilot will not light or stay lit

If you smell gas, do not light anything. Leave and, from a safe distance outdoors, call your gas utility's emergency number or 911. The Public Service Commission of Wisconsin adds: no cell phones, lights or appliances near a suspected leak.

With no gas smell, relight by the label on your heater. Montana State University Extension gives the usual sequence: control knob to OFF, wait 5 minutes for gas to clear, knob to PILOT, press and hold it while you light the pilot, keep holding for one minute, then release and turn to ON so the burner lights.

If the pilot goes out when you let go, the guide suggests holding another 10 to 15 seconds. If it still goes out, the thermocouple is defective or not in the flame, which should bathe the top half-inch of the rod. The thermocouple keeps the gas valve open only while it senses flame, so a weak one shuts off a healthy pilot.

If the burner sits behind a sealed inner door, the pilot will not hold after a correct relight, or the burner area is sooty or scorched, the next step is a technician's: the thermocouple or pilot assembly, the gas valve, anything on the gas line.

Hot water runs out fast: the depletion test

Among the causes A.O. Smith and GE list are a low setting, a broken dip tube, a failed lower element on an electric tank, or a tank too small for the household. A.O. Smith's bulletins on not enough hot water give a home test that separates them. You need a 1-gallon bucket, a watch and a candy thermometer.

StepGas tank (Bulletin 35)Electric tank (Bulletin 36)
Flow rateTime a 1-gallon bucket at the nearest faucet; gallons per minute = 60 ÷ seconds (15 seconds = 4 gpm)
RecoveryDraw about 15 gallons; reheated in about 20 to 35 minutesDraw about 15 gallons; reheated in about 45 minutes
Outlet temperature120°F to 140°F at a nearby faucet; out of range, check the thermostat
DepletionRun hot water until 60% of tank capacity is used (24 gallons from a 40-gallon tank)
ResultAbout 30°F lower is normal; a bigger drop, check the dip tubeAbout 30°F lower is normal; a bigger drop, check the lower element and dip tube

The test settings (130°F on both electric thermostats, the "A" mark on a gas dial) can be hotter than CPSC's 120°F advice, so turn the dial back down afterward. A.O. Smith adds that complaints have grown because heaters now ship set lower and with shorter dip tubes. Its sizing bulletin lists not enough hot water, heavy condensation and rust chips on the burner as signs of an undersized heater, and warns that the condensation can spoil combustion and create a carbon monoxide hazard.

Water on the floor: find the source first

A puddle does not mean the tank failed. A.O. Smith's puddle bulletin lists several sources. Dry the tank, fittings and floor, lay paper towels down and check back:

  • Condensation: appears only after a long hot-water draw and stops once the tank is above 110°F. Normal.
  • Drain valve: make sure it is fully closed; replace it if the handle cannot stop the drip.
  • Relief valve or its pipe: see the next section.
  • Inlet and outlet piping, element gaskets (electric): check each joint and gasket.
  • Gas valve threaded connection: a technician's repair.
  • The tank: if it is confirmed leaking, A.O. Smith says to replace the heater.

The full walk-through is on water heater leaking.

Relief valve dripping: pressure and thermal expansion

Watts' LF100XL-series valves relieve at 210°F, and A.O. Smith says the pressure rating should not exceed the tank's working pressure, generally 150 psi. Its relief valve bulletin names three reasons the valve opens: thermal expansion in a closed system, pressure reaching the rating, and a failed thermostat overheating the water.

250 psi is what water in a closed tank at 50 psi reaches when heated just 10 degrees, in A.O. Smith's example.

Source: A.O. Smith, Technical Bulletin 45: Thermal Expansion

A check valve at the meter, a pressure reducing valve or a water softener closes the system, so heated water has nowhere to expand. A.O. Smith's thermal expansion bulletin lists the signs: the relief valve drips during heating when no water is used, faucets drip, hot pipes creak. Its fix is a pressure reducing valve if supply pressure is above 60 to 70 psi, set to 40 to 60 psi, plus a properly sized expansion tank, and it says in capitals not to depend on the T&P valve to handle thermal expansion. Amtrol's instructions set the tank's air precharge to the cold supply pressure, with the tank empty of water. More is on water heater expansion tank.

Watts says to operate the lever at least once a year so deposits do not jam it, after checking that a discharge line is connected, since hot water will discharge. If no water flows, Watts says to turn off the heater and call a plumber. Watts says the discharge pipe must pitch down and end at least 6 inches above a floor drain, where discharge is visible.

Rumbling, popping and sizzling: sediment

A.O. Smith's mineral bulletin explains the noise: lime is inversely soluble, so the more hard water is heated, the more lime comes out. Popping is water trapped under lime deposits; sizzling is water trapped next to an element boiling to steam. A.O. Smith's repair-or-replace page adds that noise continuing after a repair such as flushing can mean a failing element or a cracked tank.

Flushing is the fix. PNNL's Building America Solution Center sequence: power off, or gas set as the manufacturer directs; cold inlet closed; a hot tap open; a hose from the drain valve to a point lower than the tank; the cold inlet opened briefly to stir sediment. Then refill until the open tap runs smoothly before restoring power, because a heater that switches on empty or partly empty can be damaged quickly. For heavy lime, A.O. Smith describes a gallon of undiluted cider vinegar left in the drained tank for at least six hours. Step by step: how to drain and flush a water heater.

Rotten-egg smell in the hot water

Rule out gas first. Some people describe the natural gas odorant as smelling like rotten eggs, sulfur or garlic, the Public Service Commission of Wisconsin says. If the smell is in the air by the heater rather than in tap water, leave and call from outside.

If only the hot water smells, the heater is the source. A.O. Smith's smelly water bulletin blames non-toxic sulfate-reducing bacteria that turn sulfate into hydrogen sulfide and thrive below 138°F. NDSU Extension adds the anode: sulfates react with a magnesium anode to produce hydrogen sulfide. GE Appliances says the smell can be reduced or eliminated in most heaters with an anode of a less active material, sometimes plus chlorinating the heater and hot lines, done by a qualified servicer or plumber.

GE warns that a non-approved anode, or no approved anode, voids its warranty. It also says raising the tank to 140°F can reduce the odor in some cases; decide that with your plumber, given CPSC's six-second burn time at 140°F. A.O. Smith's longer-term fix is treating the supply by chlorination or aeration. Anode types and inspection: water heater anode rod.

Tankless water heater not heating

Rinnai says its tankless units need 0.4 to 0.6 gallons per minute through the hot side to ignite and 0.26 gpm to keep running, so a barely open tap may never light the unit. Open the tap fully first. A 1 to 2 second temperature drop as the pipes clear is normal. Rinnai's FAQ also says to flush mineral deposits at least once a year and to check and clean the in-line screen filter. For an error code, Rinnai's advice is to contact Rinnai or the installer. Gas supply, venting and ignition faults are technician work.

Brand differences: reading the age off the label

Age drives most repair-or-replace decisions, and it is coded in the serial number on the rating label. The City of Palo Alto Utilities publishes the formats:

BrandSerial formatExampleWatch out for
RheemMonth, then year (MMYY)1209D01234 = December 2009Other formats exist
A.O. Smith (current)Year, then week (YYWW)2037… = early September 2020A week, not a month
A.O. Smith (before 2008)Second character is a month letter, then the year2C06… = March 2006A = January
Bradford WhiteFirst letter year, second letter monthHK16433183 = October 2011Year letters repeat every 20 years

GE units with a Sensing Anode need the sensing feature turned off when a special-alloy anode goes in. A.O. Smith calls the high-limit the Energy Cut Off and GE a manual reset high limit (ECO); both mean the same overheat cutoff.

What water heater repairs cost (checked November 2026)

Fixr's repair guide (updated August 29, 2025, checked in November 2026) puts the national average repair at $450, most between $150 and $750, parts and labor included.

RepairTypical pro costSymptom it fixes
Thermostat replacement$100 to $250No heat or overheating
Heating element replacement$200 to $750No heat or short supply
Anode rod replacement$125 to $300Rotten-egg smell
Pressure relief valve replacement$100 to $250Leaking or stuck valve
Dip tube replacement$100 to $250Runs out fast
Thermocouple replacement$150 to $325Pilot will not stay lit
Gas control valve, by a technician$150 to $300Burner control faults

Fixr's installation guide (updated January 27, 2026) puts a replacement at $1,400 on average, most paying $900 to $3,000: $600 to $2,500 for a tank and $1,000 to $4,000 for tankless. Haul-away runs $75 to $500 if charged, permits $25 to $1,500.

Repair or replace?

Start with age. The National Association of Home Builders' study gives 11 years for an electric tank, 10 for gas and more than 20 for tankless; A.O. Smith puts the average at about 8 to 12 years, and Rinnai says its tankless units last up to 20.

  • Replace when the tank leaks. A.O. Smith says a leaking tank, or seepage at a relief valve spud welded to the tank, is not repairable. It also lists a heater more than 10 years old, a leak around the base of the tank, or erratic operation as reasons to consider replacement.
  • Repair when the fault is a part on a sound tank: element, thermostat, thermocouple, dip tube, drain valve or relief valve.
  • Weigh it in between: compare the repair quote with the price of a new installed heater, and give more weight to replacement the older the tank is.

To extend tank life, A.O. Smith recommends inspecting the anode rod once a year and replacing it when it shows deterioration or several inches of exposed core wire.

Water heater maintenance schedule

TaskHow oftenWho says so
Check tap temperature with a thermometerAfter any setting change; aim for 120°FCPSC
Flush the tankAt least yearly; more often with hard waterA.O. Smith; Montana State Extension
Operate the relief valve leverAt least once a yearWatts
Relief valve reinspection by a plumberEvery 2 to 4 years (Watts), 5 years (A.O. Smith)Watts; A.O. Smith
Inspect the anode rodOnce a yearA.O. Smith
Check the expansion tankYearly, by a licensed professionalAmtrol
Flush a tankless unit; clean its inlet screenAt least once a year; screen periodicallyRinnai

Stop and call a pro if

  • You smell gas near the heater or a CO alarm sounds: leave and call the gas utility or 911 from outside.
  • Water is coming from the tank body or a welded fitting, not a valve, gasket or threaded joint.
  • You lift the relief valve lever and no water comes out, or the valve keeps discharging hot water.
  • The breaker trips again as soon as you reset it, or the red reset button keeps tripping.
  • Tap water reads well above the setting, or steam comes from a hot tap.
  • The burner area is sooty or scorched, flames come out of the burner door, or the pilot will not stay lit after a correct relight.
  • A tankless unit shows an error code that returns after a power reset.

Water heater troubleshooting FAQ

How do I reset my water heater?

On an electric tank: breaker off, heater verified dead, upper access panel off, then press the red reset button. A click means the high-limit had tripped because the water overheated, so A.O. Smith's flowchart goes on to check for a grounded element or a stuck thermostat. The reset button described here is on electric tanks; for a gas tank, relight the pilot by the label and see the maker's manual for any ECO or reset.

How long does a water heater last?

About 10 to 11 years for a gas or electric tank in the NAHB study, 8 to 12 by A.O. Smith's estimate, and up to 20 for a Rinnai tankless unit. The serial number on the label tells you your heater's age.

Why did my electric water heater stop working right after I drained it?

If power came back before the tank was full, an element may have been damaged; PNNL warns that a heater turned on empty or partly empty can be damaged quickly. With the power off, test the upper element: a good one reads 5 to 25 ohms.

Sources

  1. A.O. Smith, Standard Electric - No Hot Water (service flowchart)
  2. A.O. Smith, Technical Bulletin 35: Not Enough Hot Water (Gas)
  3. A.O. Smith, Technical Bulletin 36: Not Enough Hot Water (Electric)
  4. A.O. Smith, Technical Bulletin 42: Undersizing
  5. A.O. Smith, Technical Bulletin 51: Puddle on Floor
  6. A.O. Smith, Technical Bulletin 52: Leaking Temperature & Pressure Relief Valve
  7. A.O. Smith, Technical Bulletin 45: Thermal Expansion
  8. A.O. Smith, Technical Bulletin 13: Mineral Buildup
  9. A.O. Smith, Technical Bulletin 22: Smelly Water
  10. A.O. Smith, Water Heater Maintenance
  11. A.O. Smith, When to Repair or Replace Your Water Heater
  12. GE Appliances, Water Heaters: Hot Water Odor
  13. GE Appliances, Water Heater: Not Enough or No Hot Water
  14. Watts, ES-LF1L/LF1XL/LF10L/LF100XL Temperature and Pressure Relief Valves (specification sheet)
  15. Amtrol, Thermal Expansion Tanks for Potable Water: Installation and Operation Instructions
  16. Rinnai America, Residential Frequently Asked Questions
  17. U.S. Consumer Product Safety Commission, Avoiding Tap Water Scalds (Publication 5098)
  18. Pacific Northwest National Laboratory, Building America Solution Center: Flush Water Heater Tank
  19. Montana State University Extension, Water Heater Maintenance
  20. NDSU Extension, Rotten Egg Odor Only From the Hot Water Tap
  21. Public Service Commission of Wisconsin, Natural Gas Consumer Safety
  22. City of Palo Alto Utilities, Check Your Water Heater's Age
  23. National Association of Home Builders and Bank of America Home Equity, Study of Life Expectancy of Home Components (2007)
  24. Fixr, Water Heater Repair Cost (updated August 29, 2025)
  25. Fixr, Cost to Install a Water Heater (updated January 27, 2026)