Water Heater Not Heating? Test It in Order, From the Breaker to the Thermocouple

In short

On an electric tank, the most common reason for no heat is a tripped circuit breaker, A.O. Smith says. Check the breaker or the pilot first, then the reset button or the gas valve's status light. A good 4,500-watt, 240-volt element reads 12.8 ohms, plus or minus 6%, with the power off. Checked against A.O. Smith, Bradford White and Rheem manuals.

A cold shower rarely means the tank is finished. A.O. Smith says the most common reason an electric tank stops heating is a tripped circuit breaker, and on a gas tank its guidance points to the gas supply: make sure the gas valve is open, since a supply problem can also put the pilot out. For noise, smell or a dripping relief valve, start at the water heater troubleshooting guide. Every test here stays inside our safety policy: no gas line work and no work inside the electrical panel.

Quick checks first (free, about 10 minutes)

  1. Give it time. A.O. Smith's recovery guide is 30 to 40 minutes for a gas tank and 60 to 90 minutes for an electric one after a big draw. Its gas manual says to start troubleshooting if there is still no hot water two hours after lighting.
  2. Try more than one faucet. Many shower controls have a built-in mixing valve, and A.O. Smith warns that a failed one can cut the hot water a shower delivers while the tank is full. A cold shower with a hot kitchen tap is a faucet problem.
  3. Electric: look at the breaker. A tripped breaker sits at OFF or partway between ON and OFF. Reset it once; if it trips again, leave it off and read the breaker section below.
  4. Gas: valve, knob and power. A.O. Smith's lighting steps start with the manual gas valve on the supply line set to ON. The control knob must be on a temperature setting, not OFF or PILOT. VAC (vacation) mode sets the thermostat at only about 55°F, according to A.O. Smith's use and care guide. Electronic-ignition heaters with a flue damper also plug into a grounded 120-volt outlet and have an ON/OFF switch on the gas valve.
  5. Measure, do not guess. The CPSC suggests a candy or meat thermometer under the tap first thing in the morning, or two hours after anyone used hot water. GE Appliances adds that incoming water is colder in winter, so heating takes longer.

If you smell gas, stop here. Do not touch a light switch, a phone or the heater. The Public Service Commission of Wisconsin says to leave right away and call the gas utility's emergency number or 911 from a safe distance outdoors.

Causes in order, with the test for each

Ordered roughly from the cheapest check to the costliest repair. Electric rows come from the Bradford White electric service manual and A.O. Smith's no-hot-water flowchart; gas rows from the A.O. Smith, Bradford White and Rheem gas manuals.

CauseHow commonThe testWhat you will seeFix or partDIY or pro
Tripped breaker (electric)The most common reason, per A.O. SmithLook at the panelBreaker off or partwayReset onceDIY; electrician if it trips again
High-limit (ECO) tripped (electric)Means the water overheated (A.O. Smith)Power off, press the red reset buttonA click as it resetsFind why: grounded element or stuck thermostatDIY reset; repeat trips need the element test
Upper element burned outElements are the most common electric fault (Bradford White)Ohmmeter across the terminals, power offFar from the rated value, or no readingElement, about $70Careful DIY with the tank drained, or pro
Upper thermostat failedNext suspect when the upper element tests goodLive voltage testNo power reaching the elementUpper thermostat, about $41 to $71Pro for the live test
Lower element or thermostatGives a short supply, not noneOhmmeter on the lower elementSome hot water that runs out fastLower element or thermostatCareful DIY or pro
Pilot out (standing-pilot gas)A.O. Smith lists gas supply problems that put the pilot outLook through the sight windowNo pilot flameRelight by the labelDIY by the label
Thermocouple or thermopile weakListed by Rheem and Bradford White for a pilot that will not stay litMillivolt test with the pilot runningBelow 10 mV closed circuit (Bradford White)Thermocouple, about $48Technician on sealed FVIR heaters
Gas valve lockout or vapor sensor tripValves with a status lightCount the flashesA repeating code, or no lightDepends on the codeReset by the manual; technician if it returns
Single-use gas high limit openedAfter the tank overheatedPilot will not stay lit, all else checks outNot resettableNew gas control valve, $150 to $550 installedTechnician only

Electric: which half of the tank is cold?

Bradford White's spec sheet says its upright electric tanks ship wired non-simultaneous unless simultaneous operation is ordered. In its service manual, a cold tank powers the upper element first; only when the upper thermostat is satisfied does power pass to the lower thermostat. So a dead upper element or thermostat stops the whole tank:

  • No hot water at all: the upper circuit. Bradford White lists no power, loose wires, a dead upper element, a failed upper thermostat or an open ECO.
  • Some hot water that runs out fast: the lower circuit or the supply. The list adds a dead lower element, a low setting, sediment on an element, a damaged dip tube, reversed connections, very cold inlet water or an undersized heater.

The heating sequence is drawn out in how a tank water heater works.

Electric: the breaker and the red reset button

The red button sits on the thermostat behind the upper access cover, and Bradford White's procedure presses the reset on each thermostat that has one. It resets the ECO (energy cut off), a high-limit switch; A.O. Smith says a click means the water got too hot and tripped it.

  1. Switch off the heater's breaker, then confirm with a non-contact voltage tester that no wire behind the cover is live.
  2. Remove the upper cover and fold back the insulation, keeping your fingers off the terminal screws.
  3. Press the red button firmly; a click means it had tripped.
  4. Refit the insulation and cover, then restore power and allow A.O. Smith's 60 to 90 minutes.

If the button trips again, something keeps heating after the thermostat should stop it. Bradford White says repeated ECO trips are usually a grounded element; A.O. Smith adds a faulty lower thermostat. Bradford White also checks that each thermostat is in full contact with the tank, a cause of overheated water on its list. Never jumper the reset: with a grounded element, Bradford White says, the water heats continuously, limited only by the ECO.

If the breaker trips again, Bradford White says a short to ground will in most cases open the breaker, so run the ground test below. If both elements pass, HomeGuide advises an electrician for a heater that trips its breaker often.

Electric: test the heating elements

An element is a resistance wire inside a metal sheath. A burned-out wire opens the circuit; a grounded element has a path from the wire to the sheath and tank. Bradford White says to check elements first whenever there is no hot water.

Before the test: breaker off, and verify with a non-contact voltage tester that nothing is live. Then:

  1. Remove the access cover, fold back the insulation and disconnect both wires from the element's screw terminals.
  2. Set a multimeter to ohms and touch one probe to each terminal.
  3. Ground test: one probe on a terminal, the other on the element's metal flange. Bradford White says there should be no reading; any reading means the element is grounded. Repeat on the other terminal.

12.8 ohms (±6%) is the reading Bradford White expects across a good 240-volt, 4,500-watt element; outside that band, it says to replace the element.

Source: Bradford White, Residential Electric Water Heaters Service Manual 238-51544-00D

The rating is ink-stamped on the side of the element's terminal block. Bradford White's formula, ohms = volts² ÷ watts, gives these targets for 240-volt elements (our calculation, same ±6% band). A.O. Smith's flowchart accepts a wider 5 to 25 ohms.

Element rating at 240 VTarget resistance±6% bandGround test
3,500 W16.5 ohms15.5 to 17.4 ohmsNo reading (OL)
4,500 W12.8 ohms12.0 to 13.6 ohmsNo reading (OL)
5,500 W10.5 ohms9.8 to 11.1 ohmsNo reading (OL)

Replacing an element means draining the tank below it and fitting the new element with a new gasket (gasket leaks are on water heater leaking). Match the wattage and voltage on the old one. Refill until a hot tap has run full for at least three minutes, A.O. Smith's sign that the air is out, before power goes back on: Bradford White says sediment can leave an air pocket around an element and dry-fire it within seconds, so the tank must be full before power goes back on. It also ties sediment around an element to slow recovery.

Electric: the thermostats

Each thermostat is a surface-mounted switch that responds to the temperature of the tank wall. Bradford White tests them with the power on, measuring voltage across terminals, in a manual written for qualified service providers. Leave live tests to an electrician or a water heater technician.

You can still narrow it down by elimination. In A.O. Smith's no-hot-water flowchart, a reset that did not click plus a good upper element means a new upper thermostat. A reset that clicked plus two elements that pass the ground test points to thermostat contacts welded shut, most likely the lower one, which does most of the work. If everything tests good, its last step is a leak on the hot side of the plumbing. Upper and lower thermostats are separate parts; buy by the number on the old one or the heater's model.

Gas: pilot out or will not stay lit

On a standing-pilot heater, look through the sight window at the bottom of the tank for the pilot flame. If it is out, relight it by the label on the heater: Montana State University Extension's version is knob to OFF, wait 5 minutes, knob to PILOT, press and light, hold one minute, then ON. A.O. Smith's standing-pilot manual adds two stop signs: a knob that does not pop back up when released means stop and call a service technician or the gas supplier; a pilot that will not stay lit after several tries means knob to OFF and the same call. Electronic-ignition models light themselves; A.O. Smith says not to light their pilot by hand.

Why a pilot dies when you let go. The thermocouple is a rod in the pilot flame that turns heat into a small current, and Montana State says that current is what lets gas flow from the valve; the flame should bathe the top half-inch of the rod. When the current fails, the valve shuts off the gas: the safety is working. Bradford White's ICON valves use a thermopile instead, and its manual notes the valve has no power while the pilot is out.

On sealed-combustion (FVIR) heaters the burner sits behind a gasketed door, and Rheem's gas manual sends a loose or defective thermocouple, a defective safety magnet and a pilot that will not stay lit to a qualified service technician. In Bradford White's gas service manual, the technician runs the pilot for three minutes and reads the thermocouple with a millivolt meter: 10 millivolts or more closed circuit is good, and 20 to 30 millivolts open circuit is good output. Its list for a pilot that will not stay lit also covers a loose connection at the valve, a thermocouple not seated in its bracket, an open high limit in the valve, a weak magnet and a tripped thermal switch.

Gas: status lights, lockouts and limits

Count the flashes between pauses and match them to your model's manual; the same count means different things on different brands.

ValveLight patternWhat it meansNext step
A.O. Smith electronic ignition (manual 100400765)One short flash every four secondsIdle, no faultIf the water is cold, set the knob to HOT
A.O. Smith electronic ignition4 flashes, pauseECO limit lockoutSwitch OFF for 10 to 20 seconds, then ON; if it returns, the gas control valve is replaced
A.O. Smith electronic ignition6 flashes then 1, pauseFailed ignition, 20-minute soft lockoutUnplug, plug back in and relight by the manual; then a gas pressure and burner check by a qualified person
A.O. Smith electronic ignition7 flashes, pauseFlammable vapor sensor lockoutDo not touch switches; check for a gas smell and stored solvents; call a qualified service representative
Bradford White ICON (DV-series manual)No lightPilot not lit, so the valve has no powerLight the pilot; if it will not stay lit, a technician replaces the pilot assembly
Bradford White ICON2 flashes, pauseWeak pilot signalThermopile, unstable pilot or blocked pilot tube
Bradford White ICON4 flashes, pauseExcessive tank temperatureGas control replacement

The A.O. Smith manual says a light that does not flash at all may mean a lockout. It gives two homeowner jobs: inspect the air filter around the base at least once a year and, if it is dusty, switch the heater off, let it cool ten minutes and vacuum it; and store gasoline, paint thinners and cleaners elsewhere.

Older valves have no light and no reset. A.O. Smith's standing-pilot manual says its high-temperature shut-off is built into the gas control valve and cannot be reset; once it opens, the valve is replaced. Rheem calls it a single-use shut-off, and its FVIR heaters add a combustion shutoff for flammable vapors or blocked air openings, which Rheem sends to a qualified technician. Gas valve and burner work is never a homeowner job.

Lukewarm water, not cold

When some heat arrives but not enough, the A.O. Smith gas manual lists a failed mixing valve in one shower, reversed hot and cold connections or a melted dip tube (usually soon after an install; soldering copper while it is attached to the heater can melt it), a leak on the hot side that keeps the burner on almost all the time, sediment, and a heater too small for the house. A.O. Smith's electric bulletin gives a benchmark from its recovery test: about 15 gallons heated in approximately 45 minutes. The depletion test in the water heater guide separates an undersized tank from a broken dip tube.

Brand and model differences

  • A.O. Smith electronic-ignition gas (flue damper): needs 120-volt power, lights itself and reports faults as flash codes; a soft lockout waits 20 minutes before returning to normal operation.
  • Bradford White ICON gas: powered by the pilot's thermopile, so a dark light usually means the pilot is out. Its FVIR heaters have a resettable thermal switch on the inner door; the service manual tells technicians to find what tripped it before resetting.
  • Electric tanks wired simultaneous: both elements can heat at once, so the upper-first logic does not hold; Bradford White's electric spec sheet says that wiring must be specified when ordering.
  • Tankless gas: Rinnai says its units need 0.4 to 0.6 gallons per minute to ignite, so a barely open hot tap stays cold. For a fault code, it says to contact Rinnai or your installer.

What a no-heat repair costs (checked November 2026)

We checked part prices on November 24, 2026, at Sears PartsDirect and Technical Hot & Cold for the OEM part numbers shown; match the number on your old part before ordering. Labor ranges are from HomeGuide (August 7, 2025) and Fixr (updated August 29, 2025), checked November 2026.

PartSears PartsDirectTechnical Hot & ColdTypical pro cost, installed
Upper thermostat, 100108683$41.46$71.30$100 to $350 (HomeGuide); $100 to $250 (Fixr)
Lower thermostat, 100108421$59.50$43.20$100 to $350 (HomeGuide)
Element, 4,500 W 240 V$70.42 (9000094, replaced by 100108286)Not priced$100 to $350 (HomeGuide); $200 to $750 (Fixr)
Thermocouple, 100108267$48.70$47.53$100 to $325 (HomeGuide); $150 to $325 (Fixr)
Gas control valveTechnician-supplied; not priced$150 to $550 (HomeGuide); $150 to $300 (Fixr)
Igniter (electronic ignition)Model-specific; not priced$75 to $350 (HomeGuide)
New tank water heaterNot applicable$600 to $1,800 (HomeGuide)

HomeGuide adds a minimum call-out fee of $50 to $200 and plumber rates of $45 to $150 an hour, and suggests replacing a heater over 10 years old or one whose repair would cost more than half the price of a new one.

Stop and call a pro if

  • You smell gas, or the status light shows a flammable vapor lockout. Leave first and call from outside.
  • The breaker trips again as soon as you reset it, or trips while both elements pass the ground test.
  • The red reset button trips again within days, or the relief valve lets out a burst of very hot water.
  • The pilot will not stay lit after several tries, or the gas knob does not pop back up when released.
  • The same flash code returns after the reset step in the manual.
  • Any repair needs the burner door, the gas valve or the gas line opened.
  • You see scorch marks, melted wire insulation or a burnt smell behind an access cover.

Water heater not heating FAQ

How do I reset my water heater?

Electric: breaker off, wires verified dead, upper access cover off, then press the red button until it clicks. On A.O. Smith electronic gas models, an ECO lockout clears by switching the valve OFF for 10 to 20 seconds and back ON. Standing-pilot gas valves have no reset; if their high limit has opened, a technician replaces the valve.

Why does my water heater breaker keep tripping?

Bradford White says an element shorted to ground will in most cases trip the breaker. Test both elements terminal to flange with the power off; any reading means a new element. If they pass, call an electrician.

Why won't my pilot light stay lit?

Rheem's and Bradford White's lists start with the thermocouple: loose, weak or not sitting in the flame. They also name a defective safety magnet in the gas control and a tripped thermal switch or combustion shutoff. On sealed FVIR heaters those repairs belong to a technician.

Sources

  1. A.O. Smith, Water Heater Not Working: Troubleshooting Guide
  2. A.O. Smith, Standard Electric - No Hot Water (flowchart)
  3. A.O. Smith, Residential Gas Water Heater Use & Care Guide (100400765)
  4. A.O. Smith, Residential Gas Water Heaters Instruction Manual (196293-002)
  5. A.O. Smith, Technical Bulletin 36: Not Enough Hot Water (Electric)
  6. Bradford White, Residential Electric Water Heaters Service Manual (238-51544-00D)
  7. Bradford White, Upright Electric Residential Water Heater Specification Sheet
  8. Bradford White, DV Series Water Heaters Service Manual (238-51636-00D)
  9. Rheem, Residential Gas FVIR Water Heaters Use & Care Manual
  10. GE Appliances, Water Heater: Not Enough or No Hot Water
  11. Rinnai America, Frequently Asked Questions
  12. Montana State University Extension, Water Heater Maintenance
  13. CPSC, Avoiding Tap Water Scalds (Publication 5098)
  14. Public Service Commission of Wisconsin, Natural Gas Consumer Safety
  15. HomeGuide, Water Heater Repair Cost (August 7, 2025)
  16. Fixr, Water Heater Repair Cost (updated August 29, 2025)
  17. Sears PartsDirect, Upper Thermostat 100108683
  18. Sears PartsDirect, Lower Thermostat 100108421
  19. Sears PartsDirect, Heating Element 4,500 W 240 V 9000094
  20. Sears PartsDirect, Thermocouple 100108267
  21. Technical Hot & Cold, Upper Thermostat 100108683
  22. Technical Hot & Cold, Lower Thermostat 100108421
  23. Technical Hot & Cold, Thermocouple 100108267