Water Heater Leaking? Find Where the First Drop Forms Before You Replace It

In short

A water heater leaking onto the floor is often a fitting, a valve or condensation, not a failed tank. Shut off the power or gas and the cold supply, dry everything, and find where the first drop forms. A dripping relief valve usually means high water pressure or thermal expansion; water from the tank body means a new heater, $600 to $1,800 with a pro. Checked against A.O. Smith, Rheem, Watts and ICC plumbing code guidance.

Every hour its burner runs, a typical gas water heater makes about half a gallon of water vapor, A.O. Smith says, and when the tank is full of cold water some of it condenses and lands on the floor. So the first puddle is not proof of a dead tank, and A.O. Smith's gas water heater manual adds that leaks are frequently in the plumbing, not the heater. Stop the water, then find the spot where the first drop forms: it decides between a $30 part and a new heater. Other faults are in the water heater troubleshooting guide, and every step here stays inside our safety policy.

First: how fast is it leaking?

A.O. Smith's leak guide notes that tanks hold 30 to 80 gallons and treats water spraying under pressure as an emergency. If water is spurting or hissing, close the main water shutoff first.

  1. Cut the heat. Electric: switch off the water heater breaker, or the main if you cannot tell which one it is; A.O. Smith warns that water near the electrical parts is a shock hazard. Gas: close the gas shut-off valve on the supply pipe, or set the control to OFF or PILOT as the heater's label directs. If you smell gas, do not touch any switch: the Public Service Commission of Wisconsin says to leave right away and call the utility or 911 from a safe distance outdoors.
  2. Close the cold inlet valve. It is on the cold pipe at the top of the tank. The PNNL Building America guide says a lever valve is closed when it sits across the pipe and a wheel valve closes clockwise. No valve? Close the main.
  3. Drain only if it keeps leaking. Closing the inlet takes the house pressure off, but a leak low on the tank keeps draining by gravity. A hose from the drain valve to a floor drain, plus an open hot tap to let air in, empties most tanks in 20 to 30 minutes, A.O. Smith says. The water stays hot for hours, and the CPSC says water at 140°F burns skin in six seconds, and 150°F water gives most adults third-degree burns in two, so keep the hose end away from people and pets.

Keep the heater off until the tank is full again: PNNL warns that a heater that turns on empty or partly empty can be damaged quickly.

Find where the first drop forms

Water runs down a tank, so a puddle at the base can start at the top. Dry the tank, pipes, valves and floor, lay dry paper towels around the base and under each valve, and check after an hour and again after a few hours. A.O. Smith's rule: moisture that comes back within a few hours is a leak. The highest wet spot is your source; match it to the numbers below.

Gas Electric 1235671234467 Leak points 1234567 inlet and outletfittingsrelief valvedischarge pipe endelement gasket(electric)gas valve(gas)drain valvetank base
Where tank water heaters leak, after A.O. Smith's puddle bulletin. Gas heaters have no element gaskets; electric heaters have no gas valve. Schematic, not to scale.

Causes in order, with the test for each

A.O. Smith's Bulletin 51 lists seven sources of water on the floor or in the pan, ordered here by what the test costs you.

CauseHow commonThe testWhat you will seeFix or partDIY or pro
CondensationOften mistaken for a leak (A.O. Smith)Knob to PILOT, wait 8 hoursFloor stays dryNone; normal when the tank is coldNo fix needed
Inlet or outlet fittingFrequent: A.O. Smith says leaks are often in the plumbing, not the heaterDry and watch the jointDrop forms at a nut or union, crust on the threadsSnug the connector; replace a corroded oneDIY for a flex connector; pro for corroded or soldered joints
Relief valve drippingLikely where a check valve, pressure reducing valve or softener closes the system (A.O. Smith)Pressure gauge on a hose spigot, watched through a heating cyclePressure climbs while heating; over 80 psi staticExpansion tank, pressure reducing valve, or a new relief valveGauge DIY; valve and tank work by a plumber
Drain valveCan start right after the tank is drained (Fixr)Close the handle firmly; dry and watchDrip from the spout or the threadsNew drain valveDIY with the tank drained, or pro
Element gasket (electric)Electric heaters onlyBreaker off, verified dead, cover offWet insulation, rust trail from the elementGasket; threads may need resealingExperienced DIY with the tank drained, or pro
Gas valve threads (gas)Gas heaters onlyLook onlyWater where the control valve meets the tankValve removed and resealedTechnician only
TankTanks wear out with ageEverything above is dryWater from the base or the jacket seam, rustNew water heaterPro install

Condensation: a puddle that is not a leak

Hot flue gas rising through a tank full of cold water cools below its dew point, and the water in it condenses on the cold steel. A.O. Smith's condensation bulletin says newer heaters condense more than old ones because they pull more heat out of the flame, which leaves the flue gas cooler.

About ½ gallon of water vapor is produced by a typical home gas water heater for every hour the burner runs.

Source: A.O. Smith, Technical Bulletin 15: Condensation

It shows up while the burner runs, after a long shower or a refill, sometimes with drips sizzling on the burner. Rheem's gas manual adds a heavy water draw and very cold inlet water as causes.

The test: wipe up the water, turn the gas control knob to PILOT so the main burner cannot fire, and wait 8 hours. A dry floor means condensation; water means a real leak. A.O. Smith says condensation stops once the tank is above about 110°F to 115°F. In humid rooms, Bulletin 51 adds, it can also run down the cold pipe and the flue.

Leaking pipe connections on top

The cold inlet and hot outlet screw into the top of the tank, usually through short nipples and flexible connectors. A.O. Smith names loose connections and corrosion as the causes and says to look for moisture or mineral deposits where the pipes meet the tank. Wrap a dry paper towel around each joint and check it after an hour.

The fix: a braided or corrugated connector nut can be snugged with a wrench, gently; A.O. Smith warns that overtightening can damage the fitting and make the leak worse. A corroded nipple, a soldered joint or a fitting that leaks again after tightening is a job for a plumber, since A.O. Smith says corroded fittings need professional replacement.

Relief valve or its pipe dripping

The temperature and pressure (T&P) relief valve, the brass valve near the top, opens at its pressure rating, which must not exceed the tank's working pressure (generally 150 psi), or when the water near its probe passes 210°F. The International Code Council's CodeNotes on water heater safety puts it plainly: a heater working properly, on a system at code pressure, with a good valve, should not discharge at all.

A.O. Smith's relief valve bulletin reads the leak by where and how it comes out:

  • Seeping where the valve enters the tank (the spud). The spud is welded to the tank and cannot be repaired. Replace the heater.
  • Leaking at the threads of the valve. The valve is removed and the threads resealed.
  • Dribbling or weeping from the pipe end. The valve is relieving pressure, usually from thermal expansion or high water pressure.
  • A large burst of very hot water now and then. The valve opened on temperature. A.O. Smith says the only cause is a malfunctioning thermostat. Turn the heater off and call a technician.

In a house with a check valve at the meter, a pressure reducing valve or a water softener, that extra volume has nowhere to go, so pressure rises. In A.O. Smith's thermal expansion bulletin, water in a closed tank at 50 psi reaches 250 psi after just 10 degrees of heating. Other signs: hot pipes creak and faucets drip during a heating cycle, and the manual adds a toilet that runs briefly at night.

The test: screw a pressure gauge onto an outside spigot or the drain valve and note the highest reading over 24 hours, since A.O. Smith says pressure often peaks at night. Then run some hot water, close every tap and watch the gauge while the heater reheats. A needle that climbs steadily means a closed system.

80 psi is the maximum incoming water pressure most codes allow, says A.O. Smith, which recommends a working pressure no higher than 50 to 60 psi.

Source: A.O. Smith, Residential Gas Water Heater Installation Instructions and Use & Care Guide

The fix: above that, a plumber fits or adjusts a pressure reducing valve to 50 to 60 psi. A climbing needle calls for a thermal expansion tank charged to the house pressure (see water heater expansion tank). If pressure is 50 to 60 psi, the expansion tank works and flushing debris with the lever does not stop the drip, A.O. Smith says the valve may be broken and a qualified person should replace it.

Never cap or plug the relief valve or its discharge pipe; A.O. Smith warns this could cause an explosion. The ICC requires the discharge pipe to end in plain sight, no more than 6 inches above the floor or a drain, with no threads at its end so nobody can screw a cap on. Watts says to lift the test lever at least once a year with the discharge pipe in place; if no water flows, turn off the heater and call a plumber.

Drain valve dripping

The drain valve is the hose spigot near the bottom. Bulletin 51's first step is the obvious one: make sure the handle is closed tightly. Fixr notes that a drain valve can start leaking right after it has been used to drain the tank, so a drip that begins after a flush points straight at it. If the handwheel cannot stop the leak, Bulletin 51 says to replace the valve.

The tank has to be emptied to change the valve, so expect to be without hot water while the tank is drained and refilled. Montana State University Extension suggests attaching a garden hose the first time you open a valve that has not been used in years, in case it is hard to shut off.

Electric heaters: element gaskets

Each heating element passes through the tank wall, and a gasket seals the gap. A.O. Smith says a failed gasket lets water seep from the side of the tank where the element passes through. The first sign may be a wet spot below an access cover.

The test: breaker off, then confirm the heater is dead with a non-contact voltage tester. Remove the access covers and fold back the insulation without touching the terminals. Soaked insulation or a rust streak below the element points to the gasket. Refit both before power goes back on.

The fix: Bulletin 51 says the gasket can be replaced and the element threads may need resealing. The tank has to be drained first, and the breaker stays off until the tank is full again, since an element powered in an empty tank is the damage PNNL warns about.

Gas heaters: water at the gas control valve

On a gas heater, water seeping where the control valve threads into the tank wall is one of A.O. Smith's seven sources. The repair is to remove the valve and reseal its threads, which disturbs the gas connection, so it is a technician's job, not a homeowner's. A.O. Smith also says moisture near the burner or the gas line needs prompt professional help, since water can upset combustion and raise a carbon monoxide risk.

The tank itself: when the leak means replacement

Water that appears at the base, from the seam under the jacket or from the bottom of the tank, with every fitting above it dry, is the tank. A.O. Smith's manual is blunt about why: "Due to the normal corrosive action of water, the tank will eventually leak." The anode rod slows that by corroding first; A.O. Smith says anode rods usually last 3 to 5 years, and its guides tie hard water and sediment to faster corrosion. It names discolored hot water and rumbling as warning signs (parts explained in how a tank water heater works).

A.O. Smith says leaking tanks cannot be repaired. Its repair-or-replace guide puts typical service life at about 8 to 12 years and lists a heater more than 10 years old, or a leak around the base, as reasons to replace. The label on the side gives the model and serial number, and the water heater guide shows how to read the age from it.

Gas, electric and heat pump differences

  • Gas tank: condensation on the burner is normal when the tank is cold, and only gas models have the control valve thread as a leak point.
  • Electric tank: A.O. Smith says condensation can form on electric models while the tank is cold but is generally not seen because of the insulation around the tank, so treat water under an electric heater as a probable leak until the tests say otherwise. Element gaskets are the extra leak point.
  • Heat pump (hybrid) electric: these make condensate whenever the heat pump runs. GE Appliances gives about one to two quarts a day for its GeoSpring hybrid, carried away through a primary and an overflow drain. Rheem's service bulletin TB1333 ties alarm code A108 to a blocked condensate line and starts by checking where the condensate is routed and that the line is clear, then drying the sensor and pan.

Drain pans and leak sensors: limiting the damage next time

According to the ICC's 2018 IPC Essentials, a storage water heater goes in a pan wherever a tank leak could cause damage. The pan must be at least 1½ inches deep with a drain of at least ¾ inch running to a floor drain, a waste receptor or outdoors. The same text says a replacement heater does not have to add a pan where none was installed, so an older installation may have none. Under a gas heater it may not be plastic, and Rheem and A.O. Smith say it must not block the burner's air openings. A.O. Smith asks for a metal pan at least 2 inches wider than the heater and recommends an automatic leak detector with a water shutoff. Fixr prices leak detectors at $25 to $200.

What a water heater leak costs to fix (checked November 2026)

Part prices are from Sears PartsDirect (genuine OEM parts) and HomeGuide; labor is from HomeGuide (August 7, 2025) and Fixr (updated August 29, 2025), checked November 2026.

RepairPart priceTypical pro cost
Drain valve$44.60, original drain valve 100108361 (Sears PartsDirect)$100 to $200 (Fixr)
T&P relief valve$10 to $25 generic (HomeGuide); $68.78 for original valve 100108455 for A.O. Smith-family heaters (Sears PartsDirect)$50 to $300 (HomeGuide); $100 to $250 (Fixr)
Element gasket, electric$29.73, Rheem SP6708 (Sears PartsDirect)Within leak repairs, $100 to $1,000 (HomeGuide)
Thermal expansion tankNot priced$300 to $800 (HomeGuide)
Leaking tank: new tank water heaterNot applicable$600 to $1,800 installed (HomeGuide)

HomeGuide adds a minimum call-out fee of $50 to $200 and plumber rates of $45 to $150 an hour. It suggests replacing a heater over 10 years old, or when a repair costs more than half the price of a new one.

Stop and call a pro if

  • Water is coming from the tank body, the base or the seam under the jacket, not from a fitting or valve.
  • The relief valve lets out a large burst of very hot water, or keeps running after you let go of the lever.
  • You lift the relief valve lever and no water comes out at all.
  • Water is seeping where the relief valve or the gas control valve enters the tank.
  • You smell gas, or there is water around the burner, the gas valve or the electrical connections. For gas, leave first and call from outside.
  • Your gauge reads above 80 psi, or the relief valve still drips although pressure is within 50 to 60 psi and the expansion tank is working.
  • The cold inlet valve will not close, or a fitting on top is corroded.

Water heater leaking FAQ

Is a leaking water heater an emergency?

A spray, a hiss or a steady stream is: close the main water shutoff and turn off the heater now. A slow drip still needs the heater off and the cold inlet closed today, because A.O. Smith says even small leaks can cause significant water damage, and mold can grow within 24 to 48 hours once water soaks into drywall or flooring.

Can I keep using a water heater that leaks?

A.O. Smith says no: turn off the power or gas and the water and get the leak fixed first. Condensation is the exception, since it is not a leak; the 8-hour pilot test tells you which you have.

Why is my new water heater leaking?

A tank just filled with cold water condenses flue gas until it heats up, which Rheem and A.O. Smith both call normal. If it persists, check the new connections: A.O. Smith says almost all leaks at installation are at connections, not the tank.

Sources

  1. A.O. Smith, Technical Bulletin 51: Puddle on the Floor
  2. A.O. Smith, Technical Bulletin 52: Leaking Temperature and Pressure Relief Valve
  3. A.O. Smith, Technical Bulletin 15: Condensation
  4. A.O. Smith, Technical Bulletin 45: Thermal Expansion
  5. A.O. Smith, Residential Gas Water Heater Installation Instructions and Use & Care Guide (100400765, November 2025)
  6. A.O. Smith, What to Do When Your Hot Water Heater Is Leaking
  7. A.O. Smith, Water Heater Leaking
  8. A.O. Smith, When to Repair or Replace Your Water Heater
  9. Rheem, Residential Gas FVIR Water Heaters: Use & Care Manual with Installation Instructions
  10. Rheem, Technical Service Bulletin TB1333: A108 Condensate Line Blocked
  11. GE Appliances, GeoSpring Hybrid Electric Water Heater: Condensation Removal
  12. Watts, ES-LF1L/LF1XL/LF10L/LF100XL Temperature and Pressure Relief Valves (specification sheet)
  13. International Code Council, CodeNotes: Water Heater Safety in the I-Codes
  14. International Code Council, 2018 International Plumbing Code Essentials, pp. 40-41
  15. Pacific Northwest National Laboratory, Building America Solution Center: Flush Water Heater Tank
  16. U.S. Consumer Product Safety Commission, Avoiding Tap Water Scalds (Publication 5098)
  17. Montana State University Extension, Water Heater Maintenance
  18. Public Service Commission of Wisconsin, Natural Gas Consumer Safety
  19. HomeGuide, How Much Does Water Heater Repair Cost? (August 7, 2025)
  20. Fixr, How Much Does It Cost to Repair a Water Heater? (updated August 29, 2025)
  21. Sears PartsDirect, Water Heater Temperature and Pressure Relief Valve 100108455
  22. Sears PartsDirect, Water Heater Drain Valve 100108361
  23. Sears PartsDirect, Water Heater Heating Element Gasket SP6708