Water Heater Anode Rod: Signs It's Spent, the Hot-vs-Cold Smell Test, and 2026 Costs

In short

A water heater anode rod is a metal rod that corrodes so the steel tank doesn't. Check it about once a year: GE says to replace it when more than 6 inches of its core wire shows, and Bradford White (electric models) when it has worn to half its original thickness. Rotten-egg smell in the hot water only is the complaint A.O. Smith links to the rod most often. A new rod costs about $30 to $90 (checked November 2026); a plumber charges about $125 to $350. Checked against A.O. Smith, GE and Bradford White documents and Minnesota Department of Health guidance.

Hot water that smells like rotten eggs while the cold tap smells fine is the anode problem people notice. The other one is silent: the rod dissolves over the years, and when little of it is left, the steel under the tank's glass lining starts to rust. A.O. Smith says replacing a depleted rod can extend the heater's life, and GE says failing to replace a consumed rod voids the tank warranty. For other symptoms, start with the water heater troubleshooting guide; to see where the rod sits among the other parts, read how a tank water heater works.

Quick checks first (free, about 10 minutes)

  1. Smell each tap, hot and cold. The Minnesota Department of Health test: after you've been away for a few hours, smell the hot and the cold water at several faucets. The department then splits its fixes into a problem in the water heater and a problem in the well, plumbing system or softener; the usual reading is that a smell in the hot water only points at the heater. Water-heater specialists Randy Schuyler and Larry Weingarten, writing in Water Technology, add that a smell at only some fixtures is not the water heater.
  2. Smell the air near the heater. Natural gas is odorized to smell like rotten eggs or sulfur. If the smell is in the air around a gas heater rather than in the water, the Public Service Commission of Wisconsin says to leave right away and call the gas utility or 911 from outdoors.
  3. Find the rod. On most tanks it's a hex head on top, under some foam insulation (some models have a cover; check your manual). On Bradford White's electric models and some A.O. Smith electrics, the rod is built into the hot-water outlet nipple instead.
  4. Measure the clearance above the tank. Minnesota's health department puts a typical rod at 30 to 40 inches long. With less room than that, plan on a segmented rod, which A.O. Smith suggests for tight spaces.
  5. Look in a hot-side aerator, the same one you'd clean for low water pressure in one faucet. Green, blue or gray jelly points at an aluminum rod in high-pH water. Note too whether a softener feeds the heater: it speeds up rod wear.

Signs that point at the anode rod, most common first

A.O. Smith's gas-heater manual names the rotten-egg smell as the most common complaint tied to the anode; the gel and rusty-water causes depend on particular water. Most tests need only your nose or a 1-1/16-inch socket.

SignHow commonThe testWhat you will seeFix or partDIY or pro
Rotten-egg smell in the hot waterThe most common anode complaint (A.O. Smith)Smell hot and cold at several taps after a few hours awayHot smells at every tap; cold is fineLess-active rod or powered anode, plus chlorinationEither; chlorination takes care
Rod used up, no symptom yetEvery tank in time; faster with a softenerPull the rod and lookSteel core wire showing; rod worn thinNew rod, about $30 to $90DIY if it turns; pro if seized
Rod wearing fastCommon where a softener feeds the heaterPull it at six months, as A.O. Smith's electric guide asks on a new heaterDeep pitting or bare wire well before a yearInspect more oftenDIY
Gel or "jelly beads," popping in a new heaterUncommon: high-pH (8+) water areasCheck aerators and drain water; look at the rod's plugGreen, blue or gray gel; smooth plug (aluminum rod)Flush the tank, swap to magnesiumPro
Rusty, brown or black hot waterWhere iron bacteria live (iron above 0.2 ppm)Compare hot and cold; pull the rodHot only, and a heavily eaten rodChlorination plus a new rodEither
Air spitting from the hot tap after two weeks or more unusedOnly after long idle periodsOpen the farthest hot tap for several minutes, no flame nearbyA hiss like air escaping, then normal flowNothing beyond running it outDIY
Water coming from the tank bodyOften a failed tank, especially past 10 yearsDry everything and look for where the water comes fromWater seeping from the tank itself, not a fitting; a plumber should confirmNew water heaterPro

How an anode rod protects the tank

A tank heater is steel with a glass lining, and the lining is never perfect; Schuyler and Weingarten describe the anode as what protects the steel where the lining is flawed. The rod is a more active metal, usually magnesium or aluminum, cast around a steel core wire. Because it's more active than steel, it corrodes first. A.O. Smith's manual says how fast depends on the water's conductivity, not necessarily its condition, and that a corroded or pitted rod should be checked more often. The protective reaction also produces hydrogen, one of the four ingredients of the rotten-egg smell below.

NewFull thickness, smooth: commonly 5/8 in or 3/4 in thick UsedPitted and thinner: normal wear; put it back and check it more often steel core wire showing: more than 6 in ReplaceGE: replace at more than 6 in of core wire exposed at either endBradford White: replace at half the original thickness, or any bare coreA.O. Smith: replace at deterioration or several inches of exposed core wire
Reading a pulled rod. Pitting and thinning are normal; bare steel core wire is the sign. Each maker sets its own limit, so use the one for your heater's brand. Schematic, not to scale.

Rotten-egg smell from the hot water

The smell is hydrogen sulfide. A.O. Smith's gas water heater manual says four things must all be present: sulfate in the supply water, little or no dissolved oxygen, sulfate-reducing bacteria in the tank (harmless to people), and excess active hydrogen from the anode's protective action. Its Bulletin 22 adds that the bacteria thrive below 138°F, and that softeners, well water and long idle periods raise the odds. Penn State Extension explains the rod's part: a magnesium rod can chemically reduce sulfates to hydrogen sulfide. NDSU Extension says to have the water tested and base any treatment on the results. Then work through these:

  1. Swap in a less-active rod. A.O. Smith says this may reduce or eliminate the smell in some models, and GE Appliances in most heaters; NDSU names aluminum. Schuyler and Weingarten call an aluminum/zinc rod one of the most common odor fixes, and report it often works, but in softened water often doesn't.
  2. Chlorinate the tank and hot lines. A.O. Smith pairs the swap with chlorination. Its Bulletin 23: heat and cold supply off, tank drained, rod out, one gallon of household bleach per 25 gallons of tank capacity poured in through the anode opening, rod back in, tank refilled, every hot fixture run until you smell chlorine, at least an hour of contact time, then drain and flush. Heavily infected systems often need repeats, and A.O. Smith says to call a service person if any step makes you uneasy.
  3. Consider a powered anode. This impressed-current rod isn't sacrificial: it plugs into an outlet and feeds a current measured in milliamps through a titanium-clad electrode. Schuyler and Weingarten call it the most foolproof fix for the smell, and say it protects heaters where they saw rods consumed rapidly in softened water. That is field experience, not a lab result, and GE, for one, says a non-approved rod voids its warranty, so check with your heater's maker first.
  4. Temperature, with care. GE says that in certain cases a tank temperature of 140°F can reduce the odor, with temperature-limiting valves to cut scald risk. The CPSC puts a third-degree burn at six seconds for 140°F water against five minutes at 120°F.

Don't take the rod out and leave it out. NDSU lists removal as an option, but A.O. Smith says it voids the tank warranty, and the Minnesota Department of Health says it may significantly shorten the heater's life. If the smell survives a rod swap and chlorination, A.O. Smith's next step is chlorination or aeration of the water supply itself.

The rod is used up: how to pull it and read it

A spent rod gives no warning, so the test is to take it out and look. GE and A.O. Smith call for a yearly inspection, and A.O. Smith's electric guide asks for the first at six months. HomeGuide says plumbers recommend a new rod every 3 to 5 years, but your water decides, not the calendar. Both GE and A.O. Smith say a qualified servicer should do the inspection; GE cites the shock hazard and leak risk. If you do it yourself:

  1. Shut off the heat. Electric: switch off the heater's breaker. Gas: turn the gas control knob to OFF, which puts out the pilot, as A.O. Smith's maintenance guide describes.
  2. Take the pressure off. Close the cold-water valve to the heater and open a nearby hot tap. PlumbingSupply.com warns that a rod loosened under pressure can shoot out.
  3. Drain a little water. A.O. Smith says a few gallons for a top rod; for its outlet-nipple rod, Bradford White drains below the outlet. The water can scald. A full drain is a separate job: how to drain and flush a water heater.
  4. Break it loose. A.O. Smith's electric use-and-care guide calls for an impact wrench and a 6-point 1-1/16-inch socket seated fully so the head doesn't strip; a breaker bar is the hand-tool option. PlumbingSupply.com says never to hammer on the rod, because the glass lining could be damaged, and to have a helper steady a tank that isn't strapped.
  5. Lift it out. With too little headroom, A.O. Smith's method is to pull up part of the rod, cut it off and repeat. If the rod is too swollen to pass the port, PlumbingSupply.com says it still has plenty of metal: screw it back in.
  6. Read it against your brand's limit below. Pitting and thinning are normal; bare steel wire is the sign.
  7. Seal and refill. PTFE tape or an approved sealant on the new rod's threads, then tighten. Open the cold valve with the hot tap still open; A.O. Smith's electric guide says to let it run 3 minutes after a steady flow so the tank is full. Only then restore power, because an electric element run in air burns out. Check the rod's hex for drips.
BrandReplace the rod whenWhere the rod is
GEMore than 6 inches of core wire is exposed at either endNot replaceable on small point-of-use models
Bradford White (electric)Worn to half its original diameter (about 3/4 inch new), or any steel core exposedBuilt into the hot-water outlet nipple
A.O. SmithIt shows deterioration or several inches of exposed core wire; a good rod is smooth and about 1/2 inch thickTop port; a combination heat-trap nipple on some electric models

If the hex rounds off or the rod won't turn with a breaker bar, stop before you twist the tank or its pipes. PlumbingSupply.com sells hot-outlet anodes for this case: they thread into the hot-water outlet, so the seized rod can stay put.

Water softener: why the rod goes faster

A.O. Smith's Bulletin 44 explains it. A softener swaps calcium and magnesium for sodium, which lowers hardness but not conductivity; salt from a poorly rinsed resin bed raises conductivity further; and soft water stops the thin scale film that would otherwise shield bare steel at pipe connections and welds. Without that film, A.O. Smith says, the rod is used up faster.

33% drop in steel corrosion rate in A.O. Smith's corrosion cell tests once a thin scale film (under 1/16 inch) formed, after three weeks in moderate-conductivity water (17 grains hardness).

Source: A.O. Smith, Technical Bulletin 44: Water Softeners

A.O. Smith says to inspect more often with a softener; GE says artificially softened water makes the rod consume more rapidly. A six-month check on a new heater shows how fast your water eats a rod, and that sets your schedule.

Gel, "jelly beads" or popping in a new heater

A.O. Smith's Bulletin 14 covers crackling, gurgling or popping from heaters installed less than six months. In a few parts of the US with high-pH water (8 or above), the water reacts with an aluminum rod and forms aluminum hydroxide: "jelly beads" or a green, blue or gray gel in the drain water or at aerators. The plug tells you the rod type: smooth for aluminum, a weld bead for magnesium. The fix is to remove the rod, flush the tank and fit a magnesium rod, which A.O. Smith says needs abilities equal to a licensed tradesman. In a heater with lime build-up, popping is often water trapped under the deposits (Bulletin 13).

Rusty water, and air from the hot tap

A.O. Smith's Bulletin 21 says discolored hot water is rarely the tank, since a glass-lined tank seldom fails badly enough to color the water. The usual cause is iron bacteria where soluble iron is above 0.2 ppm, and heaters with them usually need new rods because the bacteria shorten anode life. The treatment is Bulletin 23 chlorination plus a new rod. If the drip forms on the tank shell itself, see water heater leaking.

A.O. Smith's gas manual also warns that hydrogen gas can build up in a hot water system unused for a long period, generally two weeks or more, and that it is extremely flammable. Before running a dishwasher or washer after a trip, open the hot tap farthest from the heater for several minutes, with no smoking or open flame nearby. A sound like air escaping through the pipe is the sign A.O. Smith says to expect if hydrogen is present.

Which rod to buy, by brand

Match the old rod's type (hex plug or outlet nipple), length and thread. PlumbingSupply.com notes its rods fit the standard 3/4-inch NPT port and that 3/4-inch-thick rods outlast 5/8-inch ones in the same water. Then pick the metal:

Rod typeHow it behavesUse it whenWatch out for
MagnesiumHighest driving voltage, used up fastestA common factory rod; A.O. Smith's fix for high-pH gelCan feed rotten-egg smell in sulfate water
AluminumLowest driving voltage, usually lasts longerNDSU's and Minnesota's suggestion for a hot-water smellGel in water with pH 8 or above
Aluminum/zinc (and tin)Less active alloy sold for odorRotten-egg smell without a softenerOften fails in softened water
PoweredTitanium electrode on outlet power; not used upSmell a rod swap didn't fixCheck your warranty first; GE, for one, says a non-approved rod voids it
  • GE: rods on small point-of-use models (such as GE02P08BAR) aren't designed to be replaced. On units with a Sensing Anode, the sensing feature must be deactivated when a special-alloy odor rod goes in, a servicer's job. A non-GE-approved rod voids the warranty.
  • Bradford White electric: its service manual has you disconnect the outlet plumbing, then unscrew the nipple and rod together, and refill the tank before power goes back on.
  • A.O. Smith: its electric guide offers a special zinc rod for odor and treats rods as a consumable, not covered by warranty. Some electric models use a combination heat-trap nipple and rod, removed with a pipe wrench.
  • Tankless: Schuyler and Weingarten note a tankless heater has no anode to react with the water.

What an anode rod costs (checked November 2026)

ItemPriceWhere
Aluminum rod, 5/8 x 42 in$30.33PlumbingSupply.com
Kenmore magnesium anode 016017$31.97Sears PartsDirect
Magnesium rod, 3/4 x 32 in$54.30PlumbingSupply.com
Hot-outlet aluminum/zinc/tin rod, 35 in$71.45PlumbingSupply.com
American Water Heaters anode 9001829$86.18Sears PartsDirect
Aluminum/zinc/tin rod, 3/4 x 42 in$89.29PlumbingSupply.com
Anode replacement by a pro$125 to $300Fixr (updated August 29, 2025)
Anode replacement by a plumber$150 to $350HomeGuide (August 7, 2025)
New tank water heater, installed$600 to $2,500Fixr (updated January 27, 2026)

A rod, a 1-1/16-inch socket and PTFE tape are the whole DIY bill, against $600 to $2,500 for a new tank. A.O. Smith puts the average tank's life at about 8 to 12 years, so the rod pays off most on a younger heater.

Stop and call a pro if

  • You smell rotten eggs or gas in the air around a gas heater, not in the water: leave the house and call the gas utility or 911 from outside.
  • Water is seeping from the tank shell itself rather than from a fitting, the drain valve or the rod's hex.
  • The rod won't turn with a breaker bar, the hex is rounding off, or the tank or its pipes start to twist.
  • You find gel or "jelly beads" in a new heater: A.O. Smith says the flush-and-swap needs licensed-tradesman skills.
  • Your GE heater has a Sensing Anode and needs a special-alloy odor rod.
  • The smell is still there after a rod swap and chlorination, or it is in the cold water too: the supply needs a water-treatment pro or well contractor.

Our safety policy explains where we draw these lines.

FAQ

How often should a water heater anode rod be replaced?

Inspect it yearly, as GE and A.O. Smith say, and replace it at your brand's limit, such as more than 6 inches of bare core wire for GE. Softened water can bring that point much sooner than HomeGuide's 3-to-5-year rule of thumb.

Can I remove the anode rod to get rid of the smell?

Removing it can stop the smell, and NDSU lists it as an option, but A.O. Smith says it voids the tank warranty and GE says running without the rod shortens the life of the glass-lined tank. A less-active rod or a powered anode treats the smell and keeps the tank protected.

Is the rotten-egg smell from hot water dangerous?

Penn State Extension says most people can smell hydrogen sulfide well below 0.5 mg/L, before it becomes a health concern, and A.O. Smith calls the bacteria behind it non-toxic. A rotten-egg smell in the air near a gas appliance is different: treat it as a gas leak.

Sources

  1. A.O. Smith, Residential Gas Water Heaters Instruction Manual 196293-002
  2. A.O. Smith, How to Maintain a Water Heater
  3. A.O. Smith, Residential Electric Water Heater Use & Care Guide
  4. A.O. Smith, Bulletin 44: Water Softeners
  5. A.O. Smith, Bulletin 14: Aluminum Hydroxide
  6. A.O. Smith, Bulletin 22: Smelly Water
  7. A.O. Smith, Bulletin 23: Chlorination Procedure
  8. A.O. Smith, Bulletin 21: Discolored Water
  9. A.O. Smith, Bulletin 13: Mineral Build-Up
  10. A.O. Smith, When to Repair or Replace
  11. GE Appliances, Anode Rod Maintenance and Service
  12. GE Appliances, Hot Water Odor
  13. Bradford White, Residential Electric Service Manual 238-51544-00D (PDF)
  14. Minnesota Department of Health, Hydrogen Sulfide and Sulfur Bacteria in Well Water
  15. Penn State Extension, Hydrogen Sulfide in Water Wells
  16. NDSU Extension, Rotten Egg Odor Only from the Hot Water Tap
  17. CPSC, Avoiding Tap Water Scalds
  18. Public Service Commission of Wisconsin, Natural Gas Consumer Safety
  19. Water Technology, Replacing Anodes, Getting Rid of Odor (2011)
  20. PlumbingSupply.com, Water Heater Anode Rods
  21. PlumbingSupply.com, How to Change a Water Heater Anode Rod
  22. Sears PartsDirect, Kenmore Mag Anode 016017
  23. Sears PartsDirect, Water Heater Anode Rod 9001829
  24. Fixr, Water Heater Repair Cost
  25. HomeGuide, Water Heater Repair Cost
  26. Fixr, Cost to Install a Water Heater